![background image](http://html.mh-extra.com/html/omega/oal-100/oal-100_installation-instructions-manual_736924019.webp)
OMEGA AUTOMATICS 2020 v3.0.2
19
Fig 7.6.2
✓
Then release the door to close on its own.
✓
The value on the screen should be around 100 ±8.
✓
Press SEL button to save the settings.
You can activate the door and scroll through parameters to make adjustments as needed to Backcheck Speed, Overload,
Holding Time etc. as needed for your installation.
You can access to our YouTube channel to watch the sample installation videos with the following link.
https://www.youtube.com/channel/UCI2d_nzMlxHzSmhMQY_e3Fg/featured
8. Trouble shooting
Possible problems
Possible solutions
Door does not open
-Check the power
-Check the ON/OFF switch
-Check the activation devices connection
-Check the display message
Display does not indicate door closed
-Check magnet position
-Check sensor wire
Display does not indicate door open
-Check magnet position
-Check sensor wire
Door stops opening halfway
-Adjust overload setting
Door does not close
-Check for rubbing on floor and ceilings
-Check the magnets and sensor wire
-Check if the gearbox has tension
Electric strike does not release
-Check wiring
-Check hardware
-Check strike connection
-Check strike voltage
Touch buttons do not respond
-Clean fingers or wipe the touch buttons
Hit ACT to begin