![background image](http://html.mh-extra.com/html/omega/oal-100/oal-100_installation-instructions-manual_736924024.webp)
OMEGA AUTOMATICS 2020 v3.0.2
24
Parameters
Description
Factory Setting
Power assist
Option for activating the door when it is pushed manually. (1_ON,
0_OFF)
0
Reactive
Option for the door to reactive while the door is in closing cycle.
(1_ON, 0_OFF)
1
Opening time
Time of opening cycle (in secs)
50
Closing Time
Time of closing cycle (in secs)
50
Latch time
Time of latching cycle (in secs)
2
Factory test
Changing value from 1 to 3 provides factory reset
1
Power assist time
Time how long will stay open when used as push to activate
15
Strike time
Separated opening time that moves the door in different speed with
no obstruction
5
Strike speed
Separated opening speed that follows the strike time strike speed
and strike time always used together
0
Ramp time
Reduces or increase the kick out of latch lower the value-stronger
the kick
12
Reverse open
Changed from 0 to 1 it will reverse read switches
0
Control mode
Changes operating mode of the controller 1-Regular, 2-Washroom,
3-Access control
1
F SEC/ F SAF
Changes the strike from fail safe to fail secure
0
PWR CLS time
Use only on HD model for length of power close
0
PWR CLS speed
Speed force of the door when it engages power closing (only HD
mode)
50
14. Re-Learn
1. Once the display indicate door closed press menu touch button and scroll down to calibrate. Press SEL touch button
the display will indicate force relearn.
2. Press SEL touch button for relearn on next activation. Exit parameter mode when the display indicate door closed
press act touch. Door operator will perform new learning.
15. Changes in software version
V1.8- Standard
Access control, washroom, motor revers
V2.0- Safety Sensor
Wiring diagram
V2.3- Encoder, safety sensor, ACT DLY, preload time, preload speed, overload to 99 bypass.