background image

                                            

     

OMEGA AUTOMATICS 2020 v3.0.2

                                                               1 

    

 

 

OAL-100 INSTALLATION INSTRUCTIONS 

 

 

 

WARNING! 

 

READ AND FOLLOW ALL INSTALLATION INSTRUCTIONS CAREFULLY! 

FAILURE TO DO SO MAY RESULT IN PERSONAL INJURY OR PROPERTY DAMAGE! 

 
AVOID ELECTRICAL SHOCK 
DISCONNECT POWER DURING INSTALLATION 
PLEASE READ ALL INSTRUCTIONS BEFORE INSTALLATION 
POWER SUPPLY REQUIRED 115+/- 5VAC-60 HZ 0.4 AMPS 
CONTROL BOARD POWER SUPPLY 16VDC 
CONTROL BOARD TO BE GROUNDED 
KEEP FINGERS & CLOTHING CLEAR OF ALL MOVING PARTS 
ADJUSTMENTS TO BE PERFORMED BY APPROVED TECHNICIAN ONLY 
ALTERATION TO ANY COMPONENTS IS PROHIBITED 
REMOVE  ANY  MECHANICAL  DEVICES  OR  LOCKS  THAT  INTERFERE  WITH  THE 
OPERATION OF THE DOOR, (OTHER THAN PARTS INTEGRATED WITH THE OPERATOR 
SYSTEM) 
OPERATOR TO BE INSTALLED 8 FEET MINIMUM ABOVE GROUND IF THERE ARE ANY 
EXPOSED MOVING PARTS 
 

Summary of Contents for OAL-100

Page 1: ...STALLATION POWER SUPPLY REQUIRED 115 5VAC 60 HZ 0 4 AMPS CONTROL BOARD POWER SUPPLY 16VDC CONTROL BOARD TO BE GROUNDED KEEP FINGERS CLOTHING CLEAR OF ALL MOVING PARTS ADJUSTMENTS TO BE PERFORMED BY APPROVED TECHNICIAN ONLY ALTERATION TO ANY COMPONENTS IS PROHIBITED REMOVE ANY MECHANICAL DEVICES OR LOCKS THAT INTERFERE WITH THE OPERATION OF THE DOOR OTHER THAN PARTS INTEGRATED WITH THE OPERATOR SYS...

Page 2: ...re as shipped 7 3 3 1 Single swing door 7 3 3 2 Double swing door 7 4 Safety information 7 4 1 Safety Instructions 7 4 2 Safety warnings 7 4 3 Residual hazard 8 5 Recommended tools 8 6 Standard torque ranges 8 7 OAL 100 installation process 9 7 1 Unpack the box and take out cover 9 7 2 Installation of bottom track on the wall 9 7 3 Motor and control board wiring 10 7 4 Arm installation 11 7 4 1 Pu...

Page 3: ...ashroom Mode 20 9 1 Parameters 20 10 Access control mode 20 10 1 Parameters 20 11 Advanced setting 21 12 Terminal description 23 13 Parameter description 23 14 Re Learn 24 15 Changes in software version 24 16 Programming encoder and parameters 25 ...

Page 4: ...operator Step 2 Mount header on the wall Step 3 Push Pull arm adjustment and installation Step 4 Test the control board Step 5 Setup the magnets Step 6 Connect the inputs outputs to the control board Step 7 Programming the system Step 8 Close the header Step 9 Place the AAADM Sticker ...

Page 5: ...01 2 Swing door operator OAL 100 motor and gearbox OA Pm01 OA Pg01 3 Swing door operator OAL 100 motor and HD gearbox OA Pm01 OA Pg10 4 Swing door operator OAL 100 control board and transformer OA Pc01 5 Swing door arms Push arm kit clear OA Pr01 6 Swing door arms Pull arm kit clear OA Pr02 7 Swing door sensors OAL 100 sensor set OA Pg 011 ...

Page 6: ...cified all dimensions are given in inches 2 5 Building codes and standards OAL 100 installation observe applicable national and local building codes 3 Product description 3 1 Intended use The OAL 100 is electromechanical operators used exclusively for opening and closing interior or exterior swing doors The OAL 100 operator installed in a surface mount header at customer site The header must be in...

Page 7: ...embly Kits Center Spindle Arm Assembly Kit or Center Hung Top Arm 2 Arm Assembly Kit depends on the type of the operator Mount Plate for Manual Door Closer LCN4040 In Ground Bottom Arm 4 Safety information 4 1 Safety Instructions This document contains important instructions for installation of the OAL 100 swing door operators Renew these instructions thoroughly prior to installation and follow th...

Page 8: ...ctural design of door area type of door and any safeguards that have been implemented Hand pinch point and crushing hazards at arm and track 5 Recommended tools 1 1 8 Allen key 2 1 4 Allen key 3 3 16 Allen key 4 5 64 Allen key 5 0 3 mm Flat screwdriver 6 9 16 Wrench 7 Ph3 Screwdriver 8 Drill Drill bits 9 Torque wrench 10 Appropriate screws for application 11 Pressure gauge 0 35 lbf Fig 5 1 6 Stand...

Page 9: ...rack on the wall Mark the location of the motor on back plate Use 1 4 allen key to take out gearbox fasteners and remove gearbox Use 1 4 allen key to take out controller fasteners and remove controller Fig 7 2 1 Use drill with drill bit that matches screw size to drill for mounting screws Always drill between channels Drill at least 6 holes on gearbox side and 4 on controller side ...

Page 10: ...e unit on top of the frame 2 above the top of the door Fig 7 2 3 Install the gearbox aligned with marks using appropriate fasteners Install control board on back plate using appropriate fasteners Fig 7 2 4 7 3 Motor and control board wiring Connect motor wire to motor connector on controller Connect limit switch wire to limit connector on controller Door frame or ...

Page 11: ... power Add jumper wire on terminals COM and ACT 2 Fig 7 4 1 1 Turn the unit on and allow it load the gearbox all the way to hard stop If the power is not provided use the arm to manually load the gearbox to hard stop by turning it until hard stop is reached Lock the gearbox with metal rod through one of the 1 2 diameter holes at bottom of the gearbox ...

Page 12: ... 2020 v3 0 2 12 Fig 7 4 1 2 Fig 7 4 1 3 Set the door to stay open at desired angle Attach arm to spindle approx 45 on door frame Fasten 3 16 socket screw on arm Level the rod and attach the block on the arm to the door ...

Page 13: ... spindle Door operator is now installed and ready for programming 7 4 2 Pull arm application First of all the operator needs to reach the hard stop itself by adding a jumper wire like Fig 7 4 1 1 or manually with the pull arm In the next step push the rod into gearbox same as Fig 7 4 1 4 to stop it then open the door to your desired fully open position and attach the pull arm to the spindle Fig 7 ...

Page 14: ...op of the door same as the following dimensions Fig 7 4 2 2 Slide the roller into the track and push the arm through the spindle then tight the screw with washer at the middle of spindle Fig 7 4 2 3 7 5 Programming Basic Setting door position switches Refer to image how the top magnetic switches on gearbox should be set up ...

Page 15: ...OMEGA AUTOMATICS 2020 v3 0 2 15 Fig 7 5 1 ...

Page 16: ...ore accessing menu door needs to be fully closed and door operator control display should say door closed Fig 7 5 2 Press menu touch button Fig 7 5 3 Press SEL touch button to access parameters Fig 7 5 4 Door closed Door closed Main Menu ...

Page 17: ...0 35 50 HD Latch speed 1 5 1 5 HD Hold open 0 OFF 1 ON 0 OFF 1 ON HD Power assist 0 OFF 1 ON 0 OFF 1 ON Reactivate 0 OFF 1 ON 0 OFF 1 ON Once parameters are set the door operator is ready for learning cycle Check the doorway for any obstacles and make sure that the door close and open smoothly Check if the door is fully closed and display shows door closed press the ACT touch button Fig 7 5 5 The ...

Page 18: ...iple test cycle to assure proper operation 7 6 Programming Heavy Duty XP operators After you follow the abovementioned steps of installation of the push or pull arm application turn on the operator then control board should recognize the encoder Press MENU touch button then press down touch button to see Calibrate Fig 7 6 1 Then press the SEL touch button Screen shows Hit ACT to begin Press ACT bu...

Page 19: ...Trouble shooting Possible problems Possible solutions Door does not open Check the power Check the ON OFF switch Check the activation devices connection Check the display message Display does not indicate door closed Check magnet position Check sensor wire Display does not indicate door open Check magnet position Check sensor wire Door stops opening halfway Adjust overload setting Door does not cl...

Page 20: ...1 Parameters Latch time Change from 2 to 0 Control mode Change from 1 to 2 Once the door is closed the display will say door closed unoccupied Fig 9 1 1 10 Access control mode 1 Install the door operator following instructions 2 Adjust parameters for basic setup 3 Follow to access control wiring diagram 4 Signal from access control panel needs to be dry to connect device and signal from access con...

Page 21: ...cess denied Fig 10 1 1 11 Advanced setting To access the advanced setting the basic setting needs to be set and door operator should run its learning cycle Press menu touch to access menu Fig 11 1 Press SEL to reach settings Door Closed Access Denied Main Menu Settings ...

Page 22: ...1 4 Then the display will show parameters to adjust desired setting Advanced setting are used for specific application of install such as access control universal washroom motor revers on HD operator opening or door exceeding 10 feet adjustments and description of parameters can be found in parameters table Settings 01 Overload 52 Settings 10 Reactivate 1 Settings 12 Opening time 20 ...

Page 23: ...ill the door perform latching cycle 5 Hold open Ratcheting mode holds the door on momentary trigger to act 1 terminal Release the door on momentary trigger 1_ON 0_OFF 0 Lock relay used for operating electric locking hardware 24VDC power terminal used to power device and looking hardware Shared input for all dry device and as 0UDC output for power devices RLY 1 is using for following applications i...

Page 24: ...se the kick out of latch lower the value stronger the kick 12 Reverse open Changed from 0 to 1 it will reverse read switches 0 Control mode Changes operating mode of the controller 1 Regular 2 Washroom 3 Access control 1 F SEC F SAF Changes the strike from fail safe to fail secure 0 PWR CLS time Use only on HD model for length of power close 0 PWR CLS speed Speed force of the door when it engages ...

Page 25: ...en position release the door to fully close and press SEL Set up the parameters following basic set up instructions Activate the door operator to perform learning cycle V2 3 beta HD only ACT DLY Changed to delay between electric strike and door operator Pre load time time now long will the door operator reverse before opening to release pressure on strike used only HD Preload speed Speed force und...

Reviews: