Automatic Rearming Notes:

• Turning on the vehicle’s ignition cancels Automatic Rearming.
• Opening a door will suspend the 90 second countdown.
• All protected zones must remain non-violated during the 90 second Automatic

Rearming period.  For example, if a vehicle door is opened during the 90 sec-
ond period, the countdown will stop.  When the door is closed, the system re-
sets and starts a new 90 second countdown period.

• The Automatic Rearming sequence is indicated by a fast flashing Red Status

Indicator Light, unless the system has been activated, in which case a Zone
Violation Code will flash instead (pages 21-22).  The ignition switch must be
turned on to erase a violation code.

• If the system is disarmed while it is activated (siren sounding and lights flashing)

Safety Disarm will cancel the Automatic Rearming for that disarming operation
only.  The next time the system is armed, Automatic Rearming will be initiated
upon the subsequent disarming.

Driver’s Door Priority Unlocking Notes:

• There is no time limitation for the second pressing of the “Disarm/Unlock”

button.  Once the button is pressed and released to Disarm the system, every
subsequent pressing of the “Disarm/Unlock” button will produce the “unlock
all doors” output, the single siren chirp and parking and dome light illumina-
tion period.  When the system is next armed, by any of the three methods, the
operation is reset so the next use of the “Disarm/Unlock” button will result in
the system Disarming and producing the “unlock driver’s door only” output.

• When disarming a system configured for Driver’s Door Priority, the user has

the option of Silent Disarming (by pressing twice the 2nd Channel Output but-
ton), and then pressing the “Unlock/Disarm” button, if needed, to unlock all of
the doors.

Emergency Override:

In the event that your transmitter is lost, damaged, or its batteries have become

exhausted, the Valet Switch and the vehicle’s ignition key may be used to disarm
the system. These Emergency Override instructions reflect a  default setting of “1
press”; but be aware that the “SecureCode” programmable feature, described on the
following page, allows the owner to customize the number of Valet Switch presses
needed for the Emergency Override.

DISARMING BY EMERGENCY OVERRIDE

Page 36

#28  Open Door Warning Upon Arming: 

Default Off

When this feature is programmed to operate, if one of the vehicle's doors is open
when the system is armed using the remote transmitter, the siren will chirp 3 times
instead of once when arming the system with the transmitter.

Programming Open Door warning Upon Arming:

  

Follow Steps 1 to 4 on

page 25; at Step 4 the Valet Switch will be pressed and released twenty eight times.
The system’s response will be twenty eight siren chirps, and the Status Light
flashing twenty eight times, pausing, then repeating.  Within 10 seconds, press and
release the transmitter’s "Arm/Lock" button to turn on Open Door Warning Upon
Arming (the siren will chirp once) or the "Disarm/Unlock" button to  turn this
feature off (the siren will chirp twice).

#29  “III” Button Operates Remote Panic: 

Default On

This feature changes the remote transmitter's operation of the Remote Panic feature
and the 3rd channel output.  When this feature is turned off, pressing the
transmitter's “

III

” button for 3 seconds will operate the 3rd channel output.  The

remote panic feature can still be operated, by pressing either the “Arm/Lock” or
“Disarm/Unlock” button for 3 seconds to activate it.  Once activated, pressing either
of these buttons will deactivate the remote panic feature.  When button “

III

” is

programmed to operate the 3rd channel output, Remote Panic can be activated by
pressing together the “

II

” and “

III

” buttons.

Programming “III” Button Operates 3rd Channel Output:

  

Follow Steps 1

to 4 on page 25; at Step 4 the Valet Switch will be pressed and released twenty nine
times.  The system’s response will be twenty nine siren chirps, and the Status Light
flashing twenty nine times, pausing, then repeating.  Within 10 seconds, press and
release the transmitter’s "Arm/Lock" button to turn on the “

III

” Button Operates 3rd

Channel Output  (the siren will chirp once) or the "Disarm/Unlock" button to have
the “

III

” button operate the Remote Panic feature (the siren will chirp twice).

#30   Remote Start Run Time 10 Or 20 Minutes:

 

Default 10 Minutes

This feature sets the period of time that the engine will run after being remotely

started.  If the engine is not stopped by transmitter or a safety circuit violation, the
engine will automatically stop upon the expiration of the selected time period.

Programming 10 or 20 Minute Run Time:

  

Follow Steps 1 to 4 on page 25;

at Step 4 the Valet Switch will be pressed and released thirty times.  The system’s
response will be thirty siren chirps, and the Status Light flashing thirty times,
pausing, then repeating.  Within 10 seconds, press and release the transmitter’s
"Arm/Lock" button to configure the system  for  20 minute remote start engine run
time (the siren will chirp once) or the "Disarm/Unlock" button to configure the
system  for 10 minute run time (the siren will chirp twice).

Summary of Contents for MAX-E

Page 1: ...tning or other acts of God This warranty limits the Company s liability to the repair or replacement of theproduct TheCompanyshallnotberesponsibleforremovaland orreinstallation charges damage to or th...

Page 2: ...LOCK 18 Doorlock Pulse Time 8 second LOCK 19 Double Unlock Pulse OFF UNLOCK 20 Arming Delay 3 Seconds LOCK 21 Pulsed Horn Steady Siren Output Steady Siren UNLOCK 22 Horn Confirmation Chirp Volume Med...

Page 3: ...the Omega MAX E system does send a signal to the Echo transceiver a few seconds is needed for this handshake to occur If the system is operated in a rapid fashion as in quickly repeating Arm and Disa...

Page 4: ...d you may The Time s Minutes will flash and may be set now When the minutes are correct While the Echo programming must be scrolled through programming mode can be exited at any point within the menu...

Page 5: ...the vehicle s ignition key to perform an emergency disarming of the security system in the event the transmitter is lost or becomes inoperable This is referred to as performing an Emergency Override...

Page 6: ...er and impact icon appears and the transceiver chips until any button is pressed and the icon remains flashing until the ignition switch is turned on The DOOR icon will indicate that the system was ac...

Page 7: ...ren will again chirp once the parking lights will again flash once the starter interrupt will engage and the Status Indicator Light will begin flashing Red slowly If programmed the vehicle s doors wil...

Page 8: ...d by the system as an open door preventing it from arming itself Although the system will not Last Door Arm while the ignition is on leaving the ignition key turned on without the engine running is no...

Page 9: ...the vehicle must remain undisturbed until that point The complete instructions for remote starting including Stick Shift Remote Starting is on pages 15 through 18 Programming Stick Shift Remote Start...

Page 10: ...gine Default Gasoline This Feature changes the system s timing of the ignition and starter output sequence for remotely starting vehicles with a diesel engine Programming Gasoline or Diesel Engine Fol...

Page 11: ...transmitter the siren will chirp 3 times instead of once when arming the system with the transmitter Programming Open Door warning Upon Arming Follow Steps 1 to 4 on page 25 at Step 4 the Valet Switc...

Page 12: ...Steps 1 to 4 on page 25 at Step 4 the Valet Switch will be pressed and released twenty seven times The system s response will be twenty seven siren chirps and the Status Light flashing twenty seven t...

Page 13: ...ion only Programming Alarm Functions Bypass Follow Steps 1 to 4 on page 25 at Step 4 the Valet Switch will be pressed and released twenty four times The system s response will be twenty four siren chi...

Page 14: ...pausing thenrepeating Within10seconds pressandreleasethetransmitter s Arm Lock buttontoconfigurethesystemwitha3secondArmingDelay thesiren will chirp once or the Disarm Unlock button to configure the...

Page 15: ...ure is determined by the type of vehicle the system is installed in this feature does save the owners of such vehicles the added expense of a special adapter Programming Door Lock Unlock Pulse Duratio...

Page 16: ...irp twice twelve times pausing then repeating Within 10 seconds press and release the transmitter s Arm Lock button to turn on Open Door Bypass Of Ignition Locking the siren will chirp once or the Dis...

Page 17: ...the ignition switch is turned on or off if one of the doors is open This feature can be useful for example for leaving others within a locked vehicle when only the driver exits the vehicle Features 9...

Page 18: ...chirponce orthe Disarm Unlock buttontoturnoffthefeature thesiren will chirp twice Programming Ignition Activated Override Follow Steps 1 to 4 on page 25 at Step 4 the Valet Switch will be pressed and...

Page 19: ...armed by simply turning the ignition switch on within 10 seconds of the system s activation After 10 seconds the Emergency Override only can disarm the system in place of the transmitter Page 17 Certa...

Page 20: ...his feature allows you to turn off the ignition switch remove your keys leave the vehicle and lock your doors while leaving the engine running To use this feature have the engine running normally from...

Page 21: ...t you and others who use your vehicle are aware of the location of the Valet Switch and its uses If the system has been upgraded with optional 2 way Omega Echo the Valet Switch is in the window unit A...

Page 22: ...Release the Valet Switch the same num ber of times as the desired feature s number The siren will chirp and the Status Indicator Light will flash as many times as the Valet Switch was pressed to indic...

Page 23: ...cator Light visually confirms the status of the system and provides a high level of visual deterrence Two colors are shown Red for security operations and Green for remote starting operations Combinat...

Page 24: ...Flashes Pause System was triggered by an open door 11 4 Red Flashes Pause System was triggered by the sensor Turning on the ignition will clear the Zone Violation Starting System Status The primary fu...

Reviews: