S P E C I F I C AT I O N S

S A F E T Y

Power:

115VAC (±15%); 2.5VA; 50/60Hz / 230VAC (±15%); 2.5VA; 50/60Hz  

Altitude:

6562 ft (2000 m) max

Installation Category:

II

Pollution Degree:

4 (Reduced to 2 by enclosure) Suitable for indoor/outdoor use

Ambient Op Temp:

-40˚ F (-40˚ C) to +150˚ F (+65˚ C)

*

Internal Bin Temp:

To +176˚ F (+80˚ C) w/alum. mount (<104˚ F (40˚ C) ambient)
To +400˚ F (+204˚ C) w/SS mount (<122˚ F (50˚ C) ambient)

Output Relay:

SPDT, 5A @ 250VAC, 30VDC maximum

External Indicators:

Red and green LEDs indicating power and operating mode

Sensitivity

:

Multi-turn potentiometer adjustment 0.5pf to 150 pf

Stability

:

±0.015pf per degree F (±0.027pf per degree C) @ 0.5pf setting

Time Delay

:

0.25 to 15 sec delay-to-activate, adjustable 
0.25 sec delay-to-deactivate, fixed

Fail-Safe:

Switch selectable - HI/LO

Build-up Immunity:

Protected via driven shield to 150 ohm load

Enclosure:

Cast alum screw-on cover, beige polyester pwdr coat, NEMA 4, IP66

Conduit Connection:

Two (2) 3/4” NPT connections

**Approvals:

CSA

US

CSA

C

Ordinary Locations, CE Mark(Ordinary location only)

Standard/Food Grade Probe

Mounting:

1-1/4” NPT alum or combo 3/4” NPT 316SS and 1-1/4” NPT alum

Probe Material:

3/8in(9.5mm) dia. 316SS probe & guard, PPS insulators

Probe Length:

16in(406mm) from alum mounting

Temp (Probe Only): PPS +450˚ F (+232˚ C) max; 
Pressure:

50 psi(3.5 bar) max (alum connection);150 psi(10 bar) max (3/4” NPT SS)

Stub Probe

Mounting:

1-1/4” NPT alum, or combo 
3/4” NPT 316SS and 1-1/4” NPT alum

Probe Material:

3/8in(9.5mm) dia. 316SS probe & guard, PPS insulators

Probe Length:

Cut to customer specification; application dependent

Temp (Probe Only): PPS +450˚ F (+232˚ C) max
Pressure:

50 psi(3.5 bar) max (aluminum); 150 psi(10 bar) max (3/4 NPT SS)

*Influenced by mounting, material thermal conductivity and ambient temperature.

General Safety  

CAUTION:  It is essential that all instructions in this manual be followed to
ensure proper operation of the equipment and safety of operating person-
nel.  Use of equipment not specified herein, may impair protection provid-
ed by equipment.  The use of this symbol is used throughout manual to
highlight important safety issues.  Please pay particular attention to these
items.

Electrical Shock Caution

Certain LV800 models are powered with HIGH VOLTAGE.  No operator
serviceable parts are inside.  All servicing is to be performed by qualified
personnel.  Each MK-2e is provided with a "protective conductor terminal"
which shall be terminated to earth ground potential (See Electrical
Installation).  This product's design complies with EN61010-1 installation
category II and pollution degree 2.

Electromagnetic Compatibility (EMC)

The LV800 was tested and found to comply with the standards listed
below.  The LV800 should not be used in residential or commercial envi-
ronments.  Compliance to EMC standards was demonstrated by means of
a test setup using the following installation methods.

1)

LV800 enclosure was connected to earth ground (protective 
earth).

2)

No specific wiring convention was used to supply power or 
to retrieve output signal from the LV800.

EMC Emissions:
Meets EN 61326-1 

Electrical Equipment for Control Use, EMC 

EN 55011

Radiated and conducted emissions 
(Class A- industrial)

EN 61000-3 

Fluctuations/Flicker

Meets FCC Part 15B:

RF Devices, Unintentional Radiators

CISPR 11 

Radiated and conducted emissions 
(Class A- industrial)

EMC Immunity:
Meets EN 61326-1

Electrical Equipment for Control Use, 
EMC 

IEC 1000-4-2

Electrostatic discharge (industrial)

IEC 1000-4-3

RF radiated EM fields (industrial)

IEC 1000-4-4

Electrical fast transients (industrial)

IEC 1000-4-5

Electrical surges (industrial)

IEC 1000-4-6

RF conducted EM energy (industrial)

IEC 1000-4-8

Power frequency magnetic fields 
(industrial)

IEC 1000-4-11

Source voltage deviation

9

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Summary of Contents for LV800 SERIES

Page 1: ...omega com e mail info omega com For latest product manuals omegamanual info LV800 SERIES Capacitance Point Level Sensors Shop online at User sGuide...

Page 2: ...8280 Guyancourt France TEL 33 0 1 61 37 2900 FAX 33 0 1 30 57 5427 Toll Free in France 0800 466 342 e mail sales omega fr Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany TEL 49 0 7056 9...

Page 3: ...of this manual pertaining to SAFETY Doing so will ensure proper oper ation of the equipment and the safety of all personnel Before discarding shipping container please inspect it thoroughly and verify...

Page 4: ...for at least 8 to 12 inches 203 305 mm of probe coverage When sensing highly conductive materials or those with a high dielectric constant the LV800 can perform as a tip sensitive sensor 2 Vessel Con...

Page 5: ...tion Doing will likely cause improper operation of the sensor Permanently Connected Equipment Disconnecting devices shall by included in the system installa tion In installations were multiple circuit...

Page 6: ...th utilize the simple 2 Step Calibration procedure One procedure sets the sensitivity with the probe being exposed to the material while the second pro cedure exposes the probe to free air only Since...

Page 7: ...tions are reversed when no material is sensed and high fail safe is selected Relay is energized Figure 7 LV800 Indicators See Figure 9 1 Yellow LED Its status describes the sensing condition of the LV...

Page 8: ...nd when no material is sensed If Fail safe High mode is used the designations are reversed Swap wire terminations of N O and N C if necessary Changing the fail safe selection is not recommended Fuse R...

Page 9: ...8 MECHANICALS Standard Probe Stub Probe DIMENSIONS ARE SHOWN IN INCHES WITH MILLIMETER EQUIVALENT IN BRACKETS...

Page 10: ...essential that all instructions in this manual be followed to ensure proper operation of the equipment and safety of operating person nel Use of equipment not specified herein may impair protection p...

Page 11: ...erwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipment sold by...

Page 12: ...bine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U Industri...

Reviews: