Warning

These safety warnings are provided to ensure the safety of

personnel and proper operation of the instrument.

·

 Read the instruction manual completely and follow all the safety

information before attempting to use or service this instrument.

·

  Use caution on any circuit: Potentially high voltages and currents

may be present and may pose a shock hazard.

·

 Read the Safety Specifications section prior to using the current

probe. Never exceed the maximum voltage ratings given.

·

  Safety is the responsibility of the operator.

·

  NEVER open the back of the instrument while connected to any

circuit or input.

·

 ALWAYS connect the current probe to the display device before

clamping the probe onto the sample being tested.

·

 ALWAYS inspect the instrument, probe, probe cable, and output

terminals prior to use. Replace any defective parts immediately.

·

 NEVER use the current probe on electrical conductors rated

above 600 V in overvoltage category III (CAT III). Use extreme

caution when clamping around bare conductors or bus bars.

International Electrical  Symbols

This symbol signifies that the probes are protected by double or

reinforced insulation. Use only specified replacement parts

when servicing the instrument.

This symbol signifies CAUTION! and requests that the user refer

to the user manual before using the instrument.

Receiving Your Shipment

Upon receiving your shipment, make sure that the contents are

consistent with the packing list. Notify Omega of any missing items. If

the equipment appears to be damaged, file a claim immediately with

the carrier and notify Omega at once, giving a detailed description of

any damage.

Not es:

2

Summary of Contents for HHM73

Page 1: ...NDUCTIVITY o pH Electrodes Testers Accessories o Benchtop Laboratory Meters o Controllers Calibrators Simulators Pumps o Industrial pH Conductivity Equipment DATA ACQUISITION o Data Acquisition Engine...

Page 2: ...l HHM73 Model HHM76 AC DC Oscilloscope Current Probes http www omega com e mail info omega com 600V CAT III 1500A DC ZERO OL ON 1500A OFF 150A OUTPUT 1500 A 1 mV A 150 A 10 mV A HHM76 AC DC CURRENT PR...

Page 3: ...nner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RE...

Page 4: ...Compatibility 11 Operating Procedure 12 Making Measurements with an Oscilloscope 12 DC Measurement 12 AC Measurement 12 Making Measurements with Accessory Connectors 13 Indicator Lights 13 Auto Off 1...

Page 5: ...ALWAYS inspect the instrument probe probe cable and output terminals prior to use Replace any defective parts immediately NEVER use the current probe on electrical conductors rated above 600 V in ove...

Page 6: ...often achieved by measuring the strength of a magnetic field created by a current carrying conductor in a semiconductor chip using the Hall effect principle When a thin semiconductor is placed at rig...

Page 7: ...k 0 5 to 1500 A DC Output Signal 10 mV A on 150 A range 1 mV A on 1500 A range Accuracy and Phase Shift 150 A Range 0 5 to 20 A 1 5 reading 0 5 A 20 to 100 A 1 5 reading 100 to 150 A DC only 2 5 readi...

Page 8: ...Range DC to 1 kHz 8 mV DC to 5 kHz 12 mV 0 1 Hz to 5 kHz 2 mV 600 A Range DC to 1 kHz 1 mV DC to 5 kHz 1 5 mV 0 1 Hz to 5 kHz 500 V Rise and Fall Time 60 A Range 100 s from 10 to 90 Vout 600 A Range 7...

Page 9: ...utes may be disabled at power up by pressing Zero button while turning on green LED blinks three times to indicate that auto off is disabled MECHANICAL Operating Temperature Range 14 to 131 F 10 to 55...

Page 10: ...ting 0 to 2000 m Non operating 0 to 12 000 m Zero Adjustment Automatic zero 10 A by simple push button increment of 25 to 40 mA Red LED goes on at push of button and turns off when zero is reached no...

Page 11: ...range Turn display device power on Turn on 7 the probe the green LED 6 should be on and the red LED 5 off If the green indicator does not come on or goes off before the probe has operated for 10 min...

Page 12: ...surement it is recommended that you zero the probe before each measurement Clamp the probe around the conductor 1 to be tested The oscilloscope should now display the measured conductor current A posi...

Page 13: ...he probe accuracy Input impedance of 1 MW 100 pF or greater When the probe is making a measurement the current carrying conductor is not broken and remains electrically isolated from the probe output...