Common  Specifications 

(HHM73 &

HHM76)

ELECTRICAL

Frequency Range: 

DC to 10 kHz at -3 dB

Load Impedance: 

>100 k

W

/100 pF

Insertion Impedance: 

0.39 m

W

 @ 50 Hz, 58 m

W

 @1000 Hz

Working Voltage: 

600 Vrms

Common Mode Voltage: 

600 Vrms

Influence of Adjacent Conductor:

< 10 mA/A at 50 Hz at 23 mm from the probe

Influence of Conductor in Jaw Opening:

0.5% reading (DC to 440 Hz)

Battery: 

9 V alkaline (NEDA 1604A, IEC 6LR61) recommended, 6LF22

Low Battery: 

Green LED when battery voltage 

³

 6.5 V

Battery Life: 

Approx. 50 hours with alkaline battery

Overload Indication:

Red LED indicates input greater than the selected range.

Auto-Off:

10 minutes (may be disabled at power-up by pressing Zero button

while turning on; green LED blinks three times to indicate that auto-off

is disabled)

MECHANICAL

Operating Temperature Range:

14¡ to 131¡F (-10¡ to 55¡C)

Storage Temperature Range:

-40¡ to 176¡F (-40¡ to 80¡C)

Temperature Influence:

£

 300 ppm/¡K or 0.3%/10¡K

Operating Relative Humidity:

10-35¡C: 90% ±5% RH (without condensation)
40-55¡C: 70% ±5% RH (without condensation)

Operation 

Examples

DC Current Measurement Example for Model HHM73 with the

Banana/BNC Connection (XF/SS Part #2111.32)

·

  Conductor carrying 25 A DC in the direction of the arrow

·

  DMM placed in DC volts mode

·

  DMM displays 250.0 mV with the probe in the 60 A (10 mV/A) range

ACV

DCV

250.0

M

V

COM

+

25 A DC

®

600V CAT III - 600A

!

DC

ZERO

OL

ON

600A

OFF

60A

OUTPUT:

600 A: 1 mV/A

60 A: 10 mV/A

HHM73

AC/DC CURRENT PROBE

6

15

Summary of Contents for HHM73

Page 1: ...NDUCTIVITY o pH Electrodes Testers Accessories o Benchtop Laboratory Meters o Controllers Calibrators Simulators Pumps o Industrial pH Conductivity Equipment DATA ACQUISITION o Data Acquisition Engine...

Page 2: ...l HHM73 Model HHM76 AC DC Oscilloscope Current Probes http www omega com e mail info omega com 600V CAT III 1500A DC ZERO OL ON 1500A OFF 150A OUTPUT 1500 A 1 mV A 150 A 10 mV A HHM76 AC DC CURRENT PR...

Page 3: ...nner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RE...

Page 4: ...Compatibility 11 Operating Procedure 12 Making Measurements with an Oscilloscope 12 DC Measurement 12 AC Measurement 12 Making Measurements with Accessory Connectors 13 Indicator Lights 13 Auto Off 1...

Page 5: ...ALWAYS inspect the instrument probe probe cable and output terminals prior to use Replace any defective parts immediately NEVER use the current probe on electrical conductors rated above 600 V in ove...

Page 6: ...often achieved by measuring the strength of a magnetic field created by a current carrying conductor in a semiconductor chip using the Hall effect principle When a thin semiconductor is placed at rig...

Page 7: ...k 0 5 to 1500 A DC Output Signal 10 mV A on 150 A range 1 mV A on 1500 A range Accuracy and Phase Shift 150 A Range 0 5 to 20 A 1 5 reading 0 5 A 20 to 100 A 1 5 reading 100 to 150 A DC only 2 5 readi...

Page 8: ...Range DC to 1 kHz 8 mV DC to 5 kHz 12 mV 0 1 Hz to 5 kHz 2 mV 600 A Range DC to 1 kHz 1 mV DC to 5 kHz 1 5 mV 0 1 Hz to 5 kHz 500 V Rise and Fall Time 60 A Range 100 s from 10 to 90 Vout 600 A Range 7...

Page 9: ...utes may be disabled at power up by pressing Zero button while turning on green LED blinks three times to indicate that auto off is disabled MECHANICAL Operating Temperature Range 14 to 131 F 10 to 55...

Page 10: ...ting 0 to 2000 m Non operating 0 to 12 000 m Zero Adjustment Automatic zero 10 A by simple push button increment of 25 to 40 mA Red LED goes on at push of button and turns off when zero is reached no...

Page 11: ...range Turn display device power on Turn on 7 the probe the green LED 6 should be on and the red LED 5 off If the green indicator does not come on or goes off before the probe has operated for 10 min...

Page 12: ...surement it is recommended that you zero the probe before each measurement Clamp the probe around the conductor 1 to be tested The oscilloscope should now display the measured conductor current A posi...

Page 13: ...he probe accuracy Input impedance of 1 MW 100 pF or greater When the probe is making a measurement the current carrying conductor is not broken and remains electrically isolated from the probe output...

Reviews: