OPERATING INSTRUCTIONS

    Power Switch

The       key turns the thermometer on or off. In the MIN MAX record mode
can not power off, must leave MIN MAX record mode then power off.

     °C °F Selecting the Temperature Scale

Readings is displayed in either degrees Celsius(°C) or degrees
Fahrenheit(°F). When the thermometer is turned on, it is set to the
temperature scale that was in use when the thermometer was last turned
off. To change the temperature scale, press the °C or °F key.

" " Button

Press " " button to toggle on and off of backlight. The backlight will switch-
off automatically after 30 seconds.

HOLD Mode

Pressing the HOLD key to enter the Data Hold mode, the "HOLD" annun-
ciator is displayed. When HOLD mode is selected, the thermometer held
the present readings and stops all further measurements.
Pressing the HOLD key again to cancel HOLD mode causing  thermometer
to resume taking measurements.
In the MIN/MAX recording mode, press HOLD key to stop the recording.
Press HOLD key again to resume recording. (Previously recorded reading
are not erased).

2

3

1

4

5

4

Summary of Contents for HH501AJ

Page 1: ...OMEGA HH501AJ Digital Thermometer...

Page 2: ...l Free in Germany 0800 82 66342 e mail nl omega com e mail germany omega com Czech Republic United Kingdom ISO 9002 Certified ul Rude armady 1868 733 01 Karvina One Omega Drive Hranice Czech Repubic R...

Page 3: ...peated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector INTRODUCTION This instrument is a 3 digit compact sized portable...

Page 4: ...year not including thermocouple error 0 1 rdg 1 0 C on 60 C to 1200 C 2 0 C on 60 C to 210 C 0 1 rdg 2 0 F on 60 F to 1999 F 4 0 F on 60 F to 346 F TemperatureCoefficient 0 1timestheapplicableaccurac...

Page 5: ...R H GENERAL Display 3 digit liquid crystal display LCD with maximum reading of 1999 Overload OL is display Battery Standard 9V battery Battery Life 100 hours typical Auto power off The meter key switc...

Page 6: ...e temperature scale press the C or F key Button Press button to toggle on and off of backlight The backlight will switch off automatically after 30 seconds HOLD Mode Pressing the HOLD key to enter the...

Page 7: ...pped and average value display OL In the this mode press HOLD key to stop the recording of readings all values are frozen press again to restart recording To prevent accidental loss of MIN MAX MAX MIN...

Page 8: ...tored reference and the present reading SET mode Relative value set and Hi Lo Limits value set 1 Press SET key to enter Relative valuse SET mode Press ENTER key can escape relative valuse set mode REL...

Page 9: ...n not 2000 0 counts all value will be memorized until yor reset it Hi Lo LIMITS mode Press Hi Lo LIMITS key to enter the Hi Lo Limits comparative mode LIMIT is displayed In the this mode the automatic...

Page 10: ...he thermometer before removing the cover Battery Replacement Power is supplied by a 9 volt transistor battery The appears on the LCD display when replacement is needed To replace the battery remove th...

Page 11: ...ty or otherwise shall not exceed the purchase price of the component upon which liability is based In no event shall OMEGA be liable for consequential incidental or special damages CONDITIONS Equipmen...

Page 12: ...rs Turbine Paddlewheel Systems Totalizers Batch Controllers pH CONDUCTIVITY pH Electrodes Testers Accessories Benchtop Laboratory Meters Controllers Calibrators Simulators Pumps Industrial pH Conducti...