pg. 11 of 33
c)
Electrical Connections – Voltage Output Units
The cable assembly should be connected to the sensor as detailed in
section 5(b) above. Power should not be applied to the sensor until all the
connections have been made and checked. Electrical connections should
be made as follows:
Wiring Schematic For Voltage Output Units.
The
RED
wire should be connected to the Positive of the power source.
The
BLACK
wire should be connected to the Negative ( Ground ) of the
power source.
The
WHITE
wire provides the signal output and should be connected to
the positive terminal of the display, data acquisition system or voltmeter
with an impedance of greater than 2500
Ω
(Ohms).
The
GREEN
wire (if present) is NOT used
Caution: Avoid high voltage static discharges to any of the
connections. Do not short the input/output signal wires or allow
them to contact the power wires at any time. DAMAGE WILL
RESULT!