Warning 

 

Warning: HIGH TEMPERATURES ARE DANGEROUS

 

 
HIGH TEMPERATURES ARE DANGEROUS:  They can cause serious burns to operators and ignite 
combustible material.  Omega Engineering has taken great care in the design of these units to protect 
operators from hazards, but operators should pay attention to the following points:

 

• USE CARE AND WEAR PROTECTIVE GLOVES TO PROTECT HANDS 
• DO NOT put hot objects on or near combustible objects 
• DO NOT operate the unit close to inflammable liquids or gases 
• DO NOT place any liquid directly in your unit 
• At all times USE COMMON SENSE 

Operator Safety 

All  operators  of  Omega  Engineering  equipment  must  have  available  the  relevant  literature  needed  to  ensure 
their safety. It is important that only suitably trained personnel operate this equipment in accordance with the 
instructions  contained  in  this  manual  and  with  general  safety  standards  and  procedures.  If  the  equipment  is 
used  in  a  manner  not  specified  by  Omega  Engineering,  the  protection  provided  by  the  equipment  to  the 
operator may be impaired. All Omega Engineering units have been designed to conform to international safety 
requirements and are fitted with a self-resetting over-temperature cutout. If a  safety problem is encountered, 
switch off at the power socket and remove the plug from the supply. Please use caution when removing probes 
and inserts as burns to the skin can occur if in contact. 

 
 

Installation 

1

.  All Omega Engineering units are supplied with a power cable. 

2

. Before connecting the power supply, check the voltage against the rating plate. Connect the power 

cable to a suitable plug according to the table below. Note that the unit must be earth grounded to 
ensure proper electrical safety. 

 

    Electrical 
connections:

 

 

220V-240V

 

110V-120V

 

Live

 

Brown

 

Black

 

Neutral

 

Blue

 

White

 

Earth ground

 

Green/yellow

 

Green

 

 

    

The fused plug supplied with the power lead for use in the UK is fitted with the following value fuse 

to protect the cable: 240V UK 5 AMP. The fuse in the unit protects the unit and the operator. Note that 
units marked 230V on the rating plate work at 220V; units marked 120V work at 110V. In both cases, 
however, the heating rate will degrade by approximately 8%. The rating plate is on the rear of the unit. 

3

. Plug the power cable into the socket on the rear of the unit. 

4

. Place the unit on a suitable bench or flat workspace, or in a fume cupboard if required, ensuring that 

the air inlet vents on the underside are free from obstruction. 
    After use, when you have finished calibrating devices, remember that the insert and your 
probe/thermometer may be very hot. Take the precautions listed earlier. 

 

 

 
 
 
 

Summary of Contents for DBCL400

Page 1: ...il info omega com For latest product manuals www omega com Above items are included with the DBCL400 Dry Block temperature calibrator Not shown is the calibration certificate and operator manual Model...

Page 2: ...gnetic interference and electrical safety regulations Specification Figures quoted are at the base of the well at the time of calibration Temperature range 5 C 9 F above ambient to 450 C 850 F Over te...

Page 3: ...safety problem is encountered switch off at the power socket and remove the plug from the supply Please use caution when removing probes and inserts as burns to the skin can occur if in contact Insta...

Page 4: ...mage both parts Always use the insert extractor to both install and remove the probe insert 4 To prevent damage to the heater block insert heaters and PRT block sensor DO NOT use the following in or a...

Page 5: ...HIS EQUIPMENT SHOULD ONLY BE DISMANTLED BY PROPERLY TRAINED PERSONNEL REMOVING THE FRONT OR REAR PANELS EXPOSES POTENTIALLY LETHAL VOLTAGES THERE ARE NO OPERATOR MAINTAINABLE PARTS WITHIN THE EQUIPMEN...

Page 6: ...oles DBCL 400 3044 Insert 2 x 1 4 2 x 3 8 holes DBCL 400 3049 Insert 1 x 5 8 1 x 1 4 holes DBCL 400 3045 Insert 2 x 1 4 2 x 1 2 holes DBCL 400 3050 Insert 1 x 11 16 1 x 1 4 holes DBCL 400 3046 Insert...

Page 7: ...U The Electromagnetic Compatibility Directive 2011 65 EU The Restriction of Hazardous Substances Directive 6 References to the relevant harmonised standards used or references to the other technical s...

Page 8: ...78 USA Canada only Engineering Service 1 800 872 9436 USA Canada only Tel 203 359 1660 Fax 203 359 7700 e mail info omega com For Other Locations Visit omega com worldwide The information contained in...

Page 9: ...y OMEGA if the unit is found to be defective it will be repaired or replaced at no charge OMEGA s WARRANTY does not apply to defects resulting from any action of the purchaser including but not limite...

Page 10: ...s M U Turbine Paddlewheel Systems M U Totalizers Batch Controllers pH CONDUCTIVITY M U pH Electrodes Testers Accessories M U Benchtop Laboratory Meters M U Controllers Calibrators Simulators Pumps M U...

Reviews: