background image

 

 

WARRANTY / DISCLAIMER    

OMEGA ENGINEERING, INC. warrants this unit to be free of defects in materials and workmanship for a period of 13 months from 
date of purchase. OMEGA Warranty adds an additional one (1) month grace period to the normal one (1) year product warranty to 
cover handling and shipping time. This ensures that OMEGA's customers receive maximum coverage on each product. If the unit 
should  malfunction,  it  must  be  returned  to  the  factory  for  evaluation.  OMEGA's  Customer  Service  Department  will  issue  an 
Authorized Return (AR) number immediately upon phone or written request. Upon examination by OMEGA, if the unit is found to be 
defective it will be repaired or replaced at no charge. OMEGA's WARRANTY does not apply to defects resulting from any action of 
the purchaser, including but not limited to mishandling, improper interfacing, operation outside of design limits, improper repair, or 
unauthorized modification. This WARRANTY is VOID if the unit shows evidence of having been tampered with or shows evidence of 
being  damaged  as  a  result  of  excessive  corrosion;  or  current,  heat  moisture  or  vibration;  improper  specification;  misapplication; 
misuse  or  other  operating  conditions  outside  of  OMEGA's  control.  Components  which  wear  are  not  warranted,  including  but  not 
limited to contact points, fuses, and triacs. 
OMEGA  is  pleased  to  offer  suggestions  on  the  use  of  its  various  products.  However,  OMEGA  neither  assumes 
responsibility for any omissions or errors nor assumes liability for any damages that result from the use of its products in 
accordance  with  information  provided  by  OMEGA,  either  verbal  or  written.  OMEGA  warrants  only  that  the  parts 
manufactured  by  it  will  be  as  specified  and  free  of  defects.  OMEGA  MAKES  NO  OTHER  WARRANTIES  OR 
REPRESENTATIONS OF ANY KIND WHATSOEVER, EXPRESSED OR IMPLIED, EXCEPT THAT OF TITLE AND ALL IMPLIED 
WARRANTIES INCLUDING  ANY WARRANTY  OF  MERCHANTABILITY  AND FITNESS FOR  A PARTICULAR  PURPOSE  ARE 
HEREBY DISCLAIMED. LIMITATION OF LIABILITY: The remedies of purchaser set forth herein are exclusive and the total 
liability  of  OMEGA  with  respect  to  this  order,  whether  based  on    contract,  warranty,  negligence,  indemnification,  strict 
liability or otherwise, shall not exceed the purchase price of the component upon which liability is based. In no event shall 
OMEGA be liable for consequential, incidental or special damages.
 
CONDITIONS: Equipment sold by OMEGA is not intended to be used, nor shall it be used: (1) as a "Basic Component" under 10 
CFR  21  (NRC),  used  in  or  with  any  nuclear  installation  or  activity;  or  (2)  in  medical  applications  or  used  on  humans.  Should  any 
Product(s)  be  used  in  or  with  any  nuclear  installation  or  activity,  medical  application,  used  on  humans,  or  misused  in  any  way, 
OMEGA assumes no responsibility as set forth in our basic WARRANTY / DISCLAIMER language, and additionally, purchaser will 
indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product(s) in 
such a manner. 

RETURN REQUESTS / INQUIRIES 

Direct  all  warranty  and  repair  requests/inquiries  to  the  OMEGA  Customer  Service  Department.  BEFORE  RETURNING  ANY 
PRODUCT(S)  TO  OMEGA,  PURCHASER  MUST  OBTAIN  AN  AUTHORIZED  RETURN  (AR)  NUMBER  FROM  OMEGA'S 
CUSTOMER SERVICE DEPARTMENT (IN ORDER TO AVOID PROCESSING DELAYS). The assigned AR number should then be 
marked on the outside of the return package and on any correspondence. 
The purchaser is responsible for shipping charges, freight, insurance and proper packaging to prevent breakage in transit. 

FOR WARRANTY RETURNS, please have the following 

information available BEFORE contacting OMEGA: 

1. P.O. number under which the product was PURCHASED. 
2. Model and serial number of the product under warranty, and 
3. Repair instructions and/or specific problems relative to the 

product.

 

FOR NON-WARRANTY REPAIRS, consult OMEGA for current 

repair charges. Have the following information available 
BEFORE contacting OMEGA: 

1. P.O. number to cover the COST of the repair. 
2. Model and serial number of product , and 
3. Repair instructions and/or specific problems relative to the 

product.

 

OMEGA's policy is to make running changes, not model changes, whenever an improvement is possible. This affords our customers the latest in 
technology and engineering. OMEGA is a registered trademark of OMEGA ENGINEERING, INC. © Copyright 2002 OMEGA ENGINEERING, INC. 
All  rights  reserved.  This  document  may  not  be  copied,  photocopied,  reproduced,  translated,  or  reduced  to  any  electronic  medium  or 
machine-readable from, in whole or in part, without prior written consent of OMEGA ENGINEERING, INC.

 

 

Where Do I Find Everything I Need for 

Process Measurement and Control? 

OMEGA…Of Course! 

TEMPERATURE 

 Thermocouple, RTD & Thermistor 

  Probes, Connectors, Panels & Assemblies 

 Wire: Thermocouple, RTD & Thermistor 

 Calibrators & Ice Point References 

 Recorders, Controllers & Process Monitors 

 Infrared Pyrometers 

PRESSURE/STRAIN AND FORCE 

 Transducers & Strain Gauges 

 Load Cells & Pressure Gauges 

 Displacement Transducers 

 Instrumentation & Accessories 

FLOW/LEVEL 

 Rotameters, Gas Mass Flowmeters & 

Flow Computers 

 Air Velocity Indicators 

 Turbine/Paddlewheel Systems 

 Totalizers & Batch Controllers 

pH/CONDUCTIVITY 

 pH Electrodes, Testers & Accessories 

 Benchtop/Laboratory Meters 

 Controllers, Calibrators, Simulators 

& Pumps 

 Industrial pH & Conductivity Equipment

 

 

DATA ACQUISITION 

 Data Acquisition & Engineering Software 

 Communications-Based 

  Acquisition Systems 

 Plug-in Cards for Apple, IBM & 

Compatibles 

 Datalogging Systems 

 Recorders, Printers & Plotters 

HEATERS 

 Heating Cable 

 Cartridge & Strip Heaters 

 Immersion & Band Heaters 

 Flexible Heaters 

 Laboratory Heaters 

ENVIRONMENTAL 
MONITORING AND CONTROL 

 Metering & Control Instrumentation 

 Refractometers 

 Pumps & Tubing 

 Air, Soil & Water Monitors 

 Industrial Water & Wastewater Treatment 

 pH, Conductivity & Dissolved Oxygen 

Instruments

 

 

M-3806/0

610

 

Summary of Contents for CL3512A

Page 1: ...zech Repubic Tel 420 69 6311627 FAX 420 69 6311114 e mail czech omega com France 9 rue Denis Papin 78190 Trappes Tel 33 130 621 400 FAX 33 130 699 120 Toll Free in France 0800 4 06342 e mail france omega com Germany Austria Daimlerstrasse 26 D 75392 Deckenpfronn Germany Tel 49 07056 3017 FAX 49 07056 8540 Toll Free in Germany 0800 82 66342 e mail germany omega com United Kingdom ISO 9002 Certified...

Page 2: ...1 1 Safety Information 1 2 Unpacking 2 0 Operation Procedure 2 1 Unit Drawing 2 2 Description of Buttons and Switches 2 3 Read Mode Procedure 2 4 Source Mode Procedure 3 0 Operator Maintenance 4 0 Specifications 5 0 Calibration Procedure ...

Page 3: ... not use this instrument when working voltages at the measurement surface over 24V AC or DC WARNING To avoid damage or burns do not make temperature measurement in microwave ovens CAUTION Repeated sharp flexing can break the thermocouple leads To prolong lead life avoid sharp bends in the leads especially near the connector 2 1 2 Unpacking Remove the packing list and verify that all equipment has ...

Page 4: ...Press the HOLD key to enter the Data Hold mode the HOLD annunciator is displayed When HOLD mode is selected the thermometer will hold the present reading and stop all further measurements Pressing the HOLD key again will cancel HOLD mode causing the thermometer to resume taking measurements Button K J T E Input Thermocouple Type Selection The TYPE key allows for selection of J K E or T thermocoupl...

Page 5: ...de to allow a particular simulated temperature to be selected once the output has been adjusted close to the desired temperature using the selector switch 6 2 3 Read Mode Procedure 1 Plug Thermocouple Sensor into input T1 and or T2 2 Turn selector switch to Input 3 Select proper thermocouple type J K T or E using type button 4 Press T1 button to read thermocouple connected to input T1 Press T2 but...

Page 6: ...sired simulated value Note There are 9 temperature range switch positions arranged from left to right representing low to high temperatures The display will read OL if the output voltage for the meter is higher than the maximum voltage for that particular thermocouple type For type T this will be in the highest 4 positions type K in the highest 3 positions type J in the highest 2 positions and typ...

Page 7: ...hermocouple Range K TYPE 0 1 C 200 C to 1372 C 328 F to 1999 F J TYPE 0 1 C 210 C to 1200 C 346 F to 1999 F T TYPE 0 1 C 200 C to 400 C 328 F to 752 F E TYPE 0 1 C 220 C to 1000 C 364 F to 1832 F Calibration Range 210 C to 1372 C 364 F to 1999 F Auto range 0 1 C 1 C 0 1 F 1 F Accuracy Accuracy is specified for operating temperatures over the range of18 C to 28 C 64 F to 82 F for 1 year not incl ud...

Page 8: ...Voltage betweenT1 and T2 during measurement 1volt 12 5 0 CL3152A Calibration Procedure Note The following calibration procedure should be performed only by qualified technicians who have access to the items as following items Equipment Thermocouple calibrator had better 10 times greater than the measured meter 1 Short CAL jumper and turn on the meter to INPUT range 2 Press key display was showed 3...

Page 9: ...13 ...

Page 10: ...DISCLAIMER language and additionally purchaser will indemnify OMEGA and hold OMEGA harmless from any liability or damage whatsoever arising out of the use of the Product s in such a manner RETURN REQUESTS INQUIRIES Direct all warranty and repair requests inquiries to the OMEGA Customer Service Department BEFORE RETURNING ANY PRODUCT S TO OMEGA PURCHASER MUST OBTAIN AN AUTHORIZED RETURN AR NUMBER F...

Reviews: