Applying the Arm Cuff

1.  Firmly insert air plug into opening located on left side of monitor unit.  

2.  With sticky nylon section facing outward, insert end of cuff underneath metal ring 

     of cuff  

3.  Fasten cuff about 

above the elbow joint.  For best results apply cuff to 

     bare arm and keep level with heart while testing

.

1-2cm (0.4-0.8'') 

.

Note:  Do not insert air plug into opening located on right side of monitor unit.  
            This opening is designed for an optional power supply only.

1-2

cm 

''

(0.4

-0.8

Testing

1.  Power On
     

" START/STOP " 

  The LCD screen will 

     appear for one second as unit performs a quick diagnosis.  A long tone indicates 
     device is ready for testing. 

Press and hold 

button until a beep sounds.

Note:  Unit will not function if residual air from previous testing is present in cuff.  
            The LCD will flash "        " until pressure is stabilized.   

2.  Pressurization
     Initial pressure is first pumped to 190 mmHg.  If the current user's systolic blood pressure
     is over 190mmHg, the unit will automatically re-inflate to the proper shelf. 

3.  Testing
      After cuff inflation, air will slowly subside as indicated by the corresponding cuff 
      pressure value.  A flashing "         " will appear simultaneously on screen signaling 
      heart beat detection. 

mmHg 

M

D

Note:  Keep relaxed during testing.  Avoid speaking or moving body parts.

4.  Result Display 
     Three short beeps sound when testing is complete.  The screen will display 
     measurements for systolic and diastolic blood pressure. 

Note: Refer to Page 

 for detail WHO Blood Pressure Classification Information

18~19

Note: If the memory is less than 3 groups , press the "MEN" button to display the last group.

Power Off

     
     turn off the power itself about 3 minutes if no operation in any mode.

The " START/ STOP" button can be pressed to turn off the unit in any mode.  The unit can 

5.Storing Test Results
    It will automatically store by date .If the number of tests surpasses the allotted 120 memories , 
    the most recent tests will appear first , thus eliminating the oldest readings.

Safety Precaution: If pressure in arm cuff becomes too extreme while testing, 
press the " START/STOP " button to turn power off.  The cuff pressure will rapidly 
dissipate once the unit is off.

Memory Check

With power off, press and hold  MEM  button to turn the unit on. The LCD will display the 
average test results from the last 3 readings.Press  MEM  button again,the LCD will display 
the last measurement memory as NO: 01 reading . Older test result in memory can be viewed 
by pressing the MEM button.

"

"

"

"

"

"

M

D

N o

ST ART

ST OP

MEM

S Y S

mmHg

DIA

mmHg

PULSE/min

Irregular Heartbeat Indicator
If the monitor detects an irregular heart rhythm two or more times during the measuring 
process, the Irregular Heartbeat Symbol "              "appears on screen along with 
measurement results.  Irregular heartbeat rhythm is defined as rhythm that is either 25% 
slower or faster than the average rhythm detected while measuring systolic blood pressure 
and diastolic blood pressure.  Consult your physician if the Irregular Heartbeat Symbol 
"             " frequently appears with your test results.

Indicator

Unit Operation

Unit Operation

Unit Operation

Unit Operation

11

12

13

14

Summary of Contents for BSP-11

Page 1: ...children The device is designed for home or clinical use All results can be read on one LCD display screen Measurements are to be taken from the upper arm of the adult Please read this manual thoroughly before using the unit Please retain this manual for future reference For specific information about your blood pressure please consult your doctor or health care professional To avoid risks and dam...

Page 2: ...bnormal readings Do not attempt to self treat these symptoms without consulting your physician first Product is designed for its intended use only Do not misuse in any way Product is not intended for infants or individuals who cannot express their intentions Do not disassemble or attempt to repair Do not use cell phones and other devices which generate strong electrical or electromagnetic fields n...

Page 3: ... cuff to your left arm and keep level with your heart Bottom of cuff should be placed approximately 1 2cm 0 4 0 8 above elbow joint See Figures D E 1 2 c m 0 4 0 8 Battery Installation Slide battery cover off as indicated by arrow Install 4 new AAA alkaline batteries according to polarity Close battery cover AC adapter jack AC adapter jack is on the right side of the monitor Medical AC adapter DC ...

Page 4: ...to Page for detail WHO Blood Pressure Classification Information 18 19 Note If the memory is less than 3 groups press the MEN button to display the last group Power Off turn off the power itself about 3 minutes if no operation in any mode The START STOP button can be pressed to turn off the unit in any mode The unit can 5 Storing Test Results It will automatically store by date If the number of te...

Page 5: ...g 100 50 6 12 18 24 Time of day Memory Deletion While in memory check mode Press and hold on for about 3 seconds to delete all history results and the LCD screen display with beep sounds Then press button to turn off the unit START STOP START STOP Classification Indicator Blood Pressure Mild Hypertension Hypertension is a dangerous disease that can affect the quality of life It can lead to a lot o...

Page 6: ...hould be checked every 2 years 9 Expected service life Approximately three years at 10 tests per day This Blood Pressure Monitor complies with the European regulations This blood pressure monitor also complies with mainly following standards included but not limited Safety standard EN 60601 1 Medical electrical equipment part 1 General requirements for safety EMC standard EN 60601 1 2 Medical elec...

Page 7: ... or poor workmanship we will repair or replace it freely The warranty does not cover damages to your Blood Pressue Monitor due to improper handling Please contact local retailer for details Warranty 25 Distributed by Omega Medical Instruments Pty Ltd Suite 1D Lvl 23 Governor Phillip Tower 1 Farrer Pl NSW 2000 Australia Customer Care Line 1300 883 257 ...

Reviews: