Systolic Blood Pressure

Diastolic Blood Pressure

Pulse Rate

LCD

Arm Cuff 

MEM  Button

"       

"        " 

Button

M onitor U nit

Air Tube

Air Plug

Air Jack

Display

A r m C uff

3.Arm Cuff

C ontents

5.Medical AC Adapter(DC6.0 V, 600mA)

   (recommended, not provided)

4.Storage Bag

2.Owner's Manual

 

1.Monitor Unit

Battery cover

 Do not mix new and old batteries simultaneously.

Replace batteries when Low Battery Indicator  

 appears on screen. 

"             "

 

Be sure battery polarity is correct.

 Do not mix battery types.  Long-life alkaline batteries are recommended.

Remove batteries from device when not in operation for more than 3 months.

 Dispose batteries properly; observe local laws and regulations.

B atter y P r ecautions

Individuals with serious circulation problems may experience discomfort. 

Consult your physician prior to use.

Contact your physician if test results regularly indicate abnormal readings. 

Do not attempt to self-treat these symptoms without consulting your 

physician first.

Product is designed for its intended use only.  Do not misuse in any way.

Product is not intended for infants or individuals who cannot express 

their intentions.
Do not disassemble or attempt to repair.
Do not use cell phones and other devices, which generate strong electrical 

or electromagnetic fields, near the device, as they may cause incorrect 

readings and interference or become interference source to the device.
Only use a recommended AC adapter  complying with EN 60601-1 and 

EN 60601-1-2

see page 6).  An unauthorized adaptor may cause fire and 

electric shock.

C aution

STOP/START

AC Adapter Jack

MEM

S Y S

mmHg

DIA

mmHg

PUL

S E

/min

STOP

ST ART

MEM

S Y S

mmHg

DIA

mmHg

PULSE/min

ST OP

ST ART

m

m

H

g

S Y

S

D

IA

m

m

H g

PL

US

E

/m

i n

ME

M

S T O

P

S TA

R T

Last 3 Results Average 

Irregular Heartbeat Indicator

Time

Date

Systolic

Blood

Pressure

Diastolic

Blood

Pressure

Pulse Rate

Low Battery Indicator

WHO Blood Pressure 

Classification Indicator

1

ARM TYPE FULLY AUTOMATIC

DIGITAL BLOOD PRESSURE MONITOR

INSTRUCTION MANUAL

MODEL: BSP-11

Safety Notice

Unit Illustration

Unit Illustration

Unit Illustration

3

4

5

6

Summary of Contents for BSP-11

Page 1: ...children The device is designed for home or clinical use All results can be read on one LCD display screen Measurements are to be taken from the upper arm of the adult Please read this manual thoroughly before using the unit Please retain this manual for future reference For specific information about your blood pressure please consult your doctor or health care professional To avoid risks and dam...

Page 2: ...bnormal readings Do not attempt to self treat these symptoms without consulting your physician first Product is designed for its intended use only Do not misuse in any way Product is not intended for infants or individuals who cannot express their intentions Do not disassemble or attempt to repair Do not use cell phones and other devices which generate strong electrical or electromagnetic fields n...

Page 3: ... cuff to your left arm and keep level with your heart Bottom of cuff should be placed approximately 1 2cm 0 4 0 8 above elbow joint See Figures D E 1 2 c m 0 4 0 8 Battery Installation Slide battery cover off as indicated by arrow Install 4 new AAA alkaline batteries according to polarity Close battery cover AC adapter jack AC adapter jack is on the right side of the monitor Medical AC adapter DC ...

Page 4: ...to Page for detail WHO Blood Pressure Classification Information 18 19 Note If the memory is less than 3 groups press the MEN button to display the last group Power Off turn off the power itself about 3 minutes if no operation in any mode The START STOP button can be pressed to turn off the unit in any mode The unit can 5 Storing Test Results It will automatically store by date If the number of te...

Page 5: ...g 100 50 6 12 18 24 Time of day Memory Deletion While in memory check mode Press and hold on for about 3 seconds to delete all history results and the LCD screen display with beep sounds Then press button to turn off the unit START STOP START STOP Classification Indicator Blood Pressure Mild Hypertension Hypertension is a dangerous disease that can affect the quality of life It can lead to a lot o...

Page 6: ...hould be checked every 2 years 9 Expected service life Approximately three years at 10 tests per day This Blood Pressure Monitor complies with the European regulations This blood pressure monitor also complies with mainly following standards included but not limited Safety standard EN 60601 1 Medical electrical equipment part 1 General requirements for safety EMC standard EN 60601 1 2 Medical elec...

Page 7: ... or poor workmanship we will repair or replace it freely The warranty does not cover damages to your Blood Pressue Monitor due to improper handling Please contact local retailer for details Warranty 25 Distributed by Omega Medical Instruments Pty Ltd Suite 1D Lvl 23 Governor Phillip Tower 1 Farrer Pl NSW 2000 Australia Customer Care Line 1300 883 257 ...