Thank you for purchasing the BSP-11 Blood Pressure Monitor.

This unit has been carefully constructed using reliable circuitry and durable materials, designed 

to bring years of accurate results and satisfactory performance when used properly.

This device is intended for non-invasive measuring an adult individuals systolic, diastolic blood 

pressure and heart rate using the oscillometric method. The device is not intended for use on 

infants and children. The device is designed for home or clinical use. All results can be read on 

one LCD display screen. Measurements are to be taken from the upper arm of the adult.

Please read this manual thoroughly before using the unit. Please retain this manual for future 

reference. For specific information about your blood pressure, please consult your doctor or 

health care professional.

To avoid risks and damages please follow all warning precautions. Operate the unit only as 

intended. Read all instructions prior to use.

WARNING SIGNS AND SYMBOLS 

Safety Notice

Contents

1

Safety Notice .............................................................................................................. 02

Unit Illustration .......................................................................................................... 04

Important Testing Guidlines ................................................................................. 07

Quick Start ................................................................................................................... 08

Unit Operation ........................................................................................................... 09

 

Battery Operation .............................................................................. 09

 

Time/Date Settings ............................................................................ 10

 

Applying The Arm Cuff ..................................................................... 11

 

Testing .................................................................................................... 12

 

Power Off .............................................................................................. 14

 

Memory Check .................................................................................... 14

 

Memory Deletion ............................................................................... 15

 

Troubleshooting ................................................................................. 16

Blood Pressure Information ................................................................................... 18

Blood Pressure Questions & Answers ................................................................. 20

Maintenance ................................................................................................................ 21

Specifications .............................................................................................................. 23

Warranty ........................................................................................................................ 25

ARM TYPE FULLY AUTOMATIC

DIGITAL BLOOD PRESSURE MONITOR

INSTRUCTION MANUAL

MODEL: BSP-11

Summary of Contents for BSP-11

Page 1: ...children The device is designed for home or clinical use All results can be read on one LCD display screen Measurements are to be taken from the upper arm of the adult Please read this manual thoroughly before using the unit Please retain this manual for future reference For specific information about your blood pressure please consult your doctor or health care professional To avoid risks and dam...

Page 2: ...bnormal readings Do not attempt to self treat these symptoms without consulting your physician first Product is designed for its intended use only Do not misuse in any way Product is not intended for infants or individuals who cannot express their intentions Do not disassemble or attempt to repair Do not use cell phones and other devices which generate strong electrical or electromagnetic fields n...

Page 3: ... cuff to your left arm and keep level with your heart Bottom of cuff should be placed approximately 1 2cm 0 4 0 8 above elbow joint See Figures D E 1 2 c m 0 4 0 8 Battery Installation Slide battery cover off as indicated by arrow Install 4 new AAA alkaline batteries according to polarity Close battery cover AC adapter jack AC adapter jack is on the right side of the monitor Medical AC adapter DC ...

Page 4: ...to Page for detail WHO Blood Pressure Classification Information 18 19 Note If the memory is less than 3 groups press the MEN button to display the last group Power Off turn off the power itself about 3 minutes if no operation in any mode The START STOP button can be pressed to turn off the unit in any mode The unit can 5 Storing Test Results It will automatically store by date If the number of te...

Page 5: ...g 100 50 6 12 18 24 Time of day Memory Deletion While in memory check mode Press and hold on for about 3 seconds to delete all history results and the LCD screen display with beep sounds Then press button to turn off the unit START STOP START STOP Classification Indicator Blood Pressure Mild Hypertension Hypertension is a dangerous disease that can affect the quality of life It can lead to a lot o...

Page 6: ...hould be checked every 2 years 9 Expected service life Approximately three years at 10 tests per day This Blood Pressure Monitor complies with the European regulations This blood pressure monitor also complies with mainly following standards included but not limited Safety standard EN 60601 1 Medical electrical equipment part 1 General requirements for safety EMC standard EN 60601 1 2 Medical elec...

Page 7: ... or poor workmanship we will repair or replace it freely The warranty does not cover damages to your Blood Pressue Monitor due to improper handling Please contact local retailer for details Warranty 25 Distributed by Omega Medical Instruments Pty Ltd Suite 1D Lvl 23 Governor Phillip Tower 1 Farrer Pl NSW 2000 Australia Customer Care Line 1300 883 257 ...

Reviews: