44
4.3.4 Fast Mode
(The Fast Mode is not available with RS485.)
During the Fast Mode there is auto high speed transmission of weight readings
to the communication. About the transmission rate, refer to the ‘Fast Mode’
square in the variables table above.
At the end, a ‘timer stamp’ is appended.
Its value is the time elapsed from
start of transmission until end of transmission, in ms.
The readings that are returned in this mode are always integers and they equal
the actual weight multiplied by 1, 10, 100, 1000 or 10000, depending upon the
resolution setting. So, although the readings are integers, due to that
multiplication the original precision is maintained. The readings are
not
rounded to the resolution. For example, if the resolution is 0.05, then the
readings transmitted by the board will be multiplied by 100, so that ‘123’ will
represent ‘1.23’.
Start_Fast_Mode(
Filtering_Level
)
Starts the Fast Mode.
Note: During the Fast Mode the LED Display is
not
updated.
Filtering_Level
(Integer):
1 = Supply readings after Filter1.
2 = Supply readings after Filter2.
Stop_Fast_Mode()
Stops the Fast Mode.
(A timer stamp is appended.
Its value is the time elapsed from start of
transmission until end of transmission, in ms.
)