41
Variables Table (cont’d)
Category
Variable Name
Description
Get
Set
Analog_Output_M
ode
0 = Manual, 1 = Auto.
V
V
Analog_Output_
Level
Voltage in the analog output, in
volts (0 – 2.5).
* The ‘Set’ is relevant only if
Analog_Output_Mode is
‘Manual’.
V
*
Auto_Hi_Voltage
When Analog_Output_Mode =
‘Auto’:
The voltage to be supplied for
weight=Auto_Hi_Weight
(in volts, up to 2.5).
V
V
Auto_Lo_Weight
When Analog_Output_Mode =
‘Auto’:
The weight for which 0V should
be supplied.
V
V
Analog
Output
(The analog
output
voltage is
measured at
pin 12 of
CONN6 with
respect to
pin 13 which
is ground.)
Auto_Hi_Weight
When Analog_Output_Mode =
‘Auto’:
The weight for which maximal
voltage (=Auto_Hi_Voltage)
should be supplied.
V
V
Input_1_Status
V
Input_2_Status
V
Input_3_Status
V
Input_4_Status
0 = off, 1 = on.
V
Input_A_Status
Status of
all
inputs at once:
#
4
#
3
#
2
#
1
#
x
= Status of input x:
0 = off, 1 = on (e.g., 0101).
V
Digital
Inputs
Toggling_Counter
A
16 bit counter that
increments when opto input
#2 is toggled
.
V