Omega Altise APC12 User Manual Download Page 9

omega altise 

 

Fan Mode 

The Fan or ventilation mode “moves” the air allowing for the recycling of air much like a general fan. 

• 

Press 

MODE

 button to choose 

FAN

 mode. 

• 

Press 

SPEED

 button to select the fan speed, either low or high. 

• 

The temperature cannot be set. 

 

Cool Mode 

The cooling mode uses a refrigerated circuit (compressor) to cool the room by transferring the heat from the 
inside to the outside through the air exhaust hose and cooling the air that it returns to the room. 

• 

Press 

MODE

 button to choose 

COOL

 mode. 

• 

In 

COOL

 mode the temperature of this unit is pre-set to 24

0

C. 

• 

Press 

UP

 or 

DOWN

 buttons or to set the desired temperature between 18-32

0

C. As you set the 

temperature the display window will show the temperature you set. Otherwise it will show the ambient 
temperature of the room. 

• 

Press 

SPEED

 button or to select the fan speed, either low or high. 

• 

In 

COOL

 mode the unit will use Aqua Chill technology to improve the cooling efficiency of the unit. See 

the Aqua Chill section for further details. 

 

Please Note: The temperature adjustment setting is not a direct correlation to the ambient room 

temperature. For example, adjusting the setting to 18

0

C will not necessarily bring the ambient room 

temperature down to 18

0

C. 

 

Heat Mode (APC12RC only) 

The heating mode uses a reversed refrigerated circuit (compressor) to warm the room by transferring the 
cold from the inside to the outside through the air exhaust hose and warming the air that it returns to the 
room. 

• 

Press 

MODE

 button to choose 

HEAT

 mode. 

• 

In 

HEAT

 mode the temperature of this unit is pre-set to 20

0

C. 

• 

Press 

UP

 or 

DOWN

 buttons or to set the desired temperature between 18-32

0

C. As you set the 

temperature the display window will show the temperature you set. Otherwise it will show the ambient 
temperature of the room. 

• 

Press 

SPEED

 button or to select the fan speed, either low or high. 

 

Timer – On 

• 

When the unit is switched off, press 

TIMER

 button to set timer-on. 

• 

Press 

UP

 or 

DOWN

 buttons to adjust the time from 1hr to 24hrs. 

• 

Time will vary 1hr accordingly for each press of either the 

UP

 or 

DOWN

 buttons. 

• 

At this stage also select the mode/settings that you wish the unit to turn on with. 

• 

When the set time is reached the unit will turn on automatically. 

Summary of Contents for APC12

Page 1: ...PORTABLE AIR CONDITIONER APC12 APC12RC APC14...

Page 2: ...upervised or instruction concerning use of the appliance by a responsible person for their safely 7 Do not use the appliance for any other purpose than its intended use 8 The appliance must not be use...

Page 3: ...nsferring the cold from the inside to the outside through the air exhaust hose and warming the air that it returns to the room Features of your new Portable Air Conditioner No costly installation requ...

Page 4: ...Controls Electronic Remote Electronic Remote Electronic Remote Aqua Chill Pump over Pump over Pump over Water injection port Yes Yes Yes Water full alarm Yes Yes Yes Water drainage Yes Yes Yes Directi...

Page 5: ...ilter 6 Air inlet grille 7 Power cord storage and water injection port 8 Exhaust outlet adapter 9 Water drainage port 10 Removable air filter 11 Accessories 11 Flexible hose exhaust 12 Adjustable wind...

Page 6: ...al and horizontal windows However it may be necessary for you to modify some aspects of the installation procedures for certain types of windows Open the window and insert the window kit to cover the...

Page 7: ...for maximum performance This length has been designed according to the specifications of the air conditioner Do not use an extension or exchange with a different hose as that may lead to malfunction D...

Page 8: ...tor 22 High fan speed indicator Operating Instructions On Off Press ON OFF button the unit will start in AUTO mode To turn the unit off press ON OFF button again Please note The display window will sh...

Page 9: ...e Note The temperature adjustment setting is not a direct correlation to the ambient room temperature For example adjusting the setting to 180 C will not necessarily bring the ambient room temperature...

Page 10: ...in heating mode the set temperature will decrease 10 C at the end of the 1st hour and another 10 C at the end of the second hour and then maintain that temperature until switch off or manually changed...

Page 11: ...in refer to the drainage section Adding Water To utilise the full potential of the cool mode of your portable air conditioner we recommend approx 1000mls of water be added to the water injection port...

Page 12: ...that you do not move the unit around without firstly draining the internal tank If water is left in the unit then it may spill out onto the floor or carpet Continuous Drainage If you wish to operate t...

Page 13: ...l detergent 3 Rinse the filter and dry it in a shaded place 4 Push the air filter back into the original position 5 Alternatively suction the filters using a vacuum cleaner with the dusting brush atta...

Page 14: ...vated Turn the unit off wait 3 minutes until the temperature has decreased then turn the unit on again The exhaust tube is attached incorrectly or is bent Set the exhaust tube correctly as indicated i...