background image

omega altise 

 

Introduction 

Thank you for choosing an omega altise portable air conditioner. This manual contains information, 
regulations and warnings which are of fundamental importance if the appliance is to be installed correctly 
and the highest performance, in the safest possible conditions, is to be obtained. We suggest that you read 
the manual carefully before installing or starting up the unit. 

This portable air-conditioning unit is of the mono tube type, is conveniently transportable (on wheels) with an 
air operating system for domestic use. This unit has the following settings for ease of use: 

• 

Ventilate (fan); 

• 

Cool; and 

• 

Heat (APC12RC only). 

The ventilation mode “moves” the air allowing for the recycling of air much like a general fan. 

The cooling mode uses a refrigerated circuit (compressor) to cool the room by transferring the heat from the 
inside to the outside through the air exhaust hose and cooling the air that it returns to the room. 

The heating mode uses a reversed refrigerated circuit (compressor) to warm the room by transferring the 
cold from the inside to the outside through the air exhaust hose and warming the air that it returns to the 
room. 

 

 

Features of your new Portable Air-Conditioner 

• 

No costly installation required. 

• 

Easily moved with castors and handle.  

• 

Electronic control panel. 

• 

Remote control. 

• 

Low noise and strong breeze.  

• 

On/off timer function. 

• 

Three-minute restart delay to protect compressor.  

 

 

Energy Saving Tips 

1.  Do not cover or restrict the airflow from the outlet or inlet grilles.  

2.  The minimum distance from furniture and walls should be 50cm.  

3.  Keep blinds and /or draperies, on any windows, closed during the sunniest part of the day.  

4.  Keep the filters clean. Under normal conditions, the 

filters should be cleaned approximately every 2 

weeks 

(please see the maintenance section for further instructions). Since the filters remove airborne 

particles, more frequent cleaning maybe necessary, depending on the indoor air quality and if you have 
pets inside the home. 

5.  Set the fan speed switch to high cool and the thermostat to the coolest position for the initial start-up, 

then set the Fan switch to Low cool and lower the thermostat to a comfortable setting.  

6.  Ensure all windows and doors to the room you are operating the unit in are closed. 

 

Summary of Contents for APC12

Page 1: ...PORTABLE AIR CONDITIONER APC12 APC12RC APC14...

Page 2: ...upervised or instruction concerning use of the appliance by a responsible person for their safely 7 Do not use the appliance for any other purpose than its intended use 8 The appliance must not be use...

Page 3: ...nsferring the cold from the inside to the outside through the air exhaust hose and warming the air that it returns to the room Features of your new Portable Air Conditioner No costly installation requ...

Page 4: ...Controls Electronic Remote Electronic Remote Electronic Remote Aqua Chill Pump over Pump over Pump over Water injection port Yes Yes Yes Water full alarm Yes Yes Yes Water drainage Yes Yes Yes Directi...

Page 5: ...ilter 6 Air inlet grille 7 Power cord storage and water injection port 8 Exhaust outlet adapter 9 Water drainage port 10 Removable air filter 11 Accessories 11 Flexible hose exhaust 12 Adjustable wind...

Page 6: ...al and horizontal windows However it may be necessary for you to modify some aspects of the installation procedures for certain types of windows Open the window and insert the window kit to cover the...

Page 7: ...for maximum performance This length has been designed according to the specifications of the air conditioner Do not use an extension or exchange with a different hose as that may lead to malfunction D...

Page 8: ...tor 22 High fan speed indicator Operating Instructions On Off Press ON OFF button the unit will start in AUTO mode To turn the unit off press ON OFF button again Please note The display window will sh...

Page 9: ...e Note The temperature adjustment setting is not a direct correlation to the ambient room temperature For example adjusting the setting to 180 C will not necessarily bring the ambient room temperature...

Page 10: ...in heating mode the set temperature will decrease 10 C at the end of the 1st hour and another 10 C at the end of the second hour and then maintain that temperature until switch off or manually changed...

Page 11: ...in refer to the drainage section Adding Water To utilise the full potential of the cool mode of your portable air conditioner we recommend approx 1000mls of water be added to the water injection port...

Page 12: ...that you do not move the unit around without firstly draining the internal tank If water is left in the unit then it may spill out onto the floor or carpet Continuous Drainage If you wish to operate t...

Page 13: ...l detergent 3 Rinse the filter and dry it in a shaded place 4 Push the air filter back into the original position 5 Alternatively suction the filters using a vacuum cleaner with the dusting brush atta...

Page 14: ...vated Turn the unit off wait 3 minutes until the temperature has decreased then turn the unit on again The exhaust tube is attached incorrectly or is bent Set the exhaust tube correctly as indicated i...