background image

omega altise 

 

Aqua Chill Technology 

When operating in Cool Mode this unit uses a self-evaporative system that extracts water from humid 
environments and collects it in an internal water tank. 

Once sufficient water is collected it is recycled over the condenser, assisting to cool the condenser and 
internal refrigerant gas faster than only air. Cooler condenser and refrigerant, means improved cooling 
efficiency and performance of the unit.  

Some of the water recycled over the compressor is evaporated and expelled from the machine as water 
vapour through the flexible exhaust hose. 

During very humid conditions the collection of water may be in excess of the evaporation rate and the 
internal water tank may become full and cause the 

WATER FULL

 indicator to trigger. In this instance the 

compressor will shut off automatically and a buzzer will sound. Pressing any button will stop the buzzer. You 
will need to empty the water tank before the unit will work again (refer to the drainage section). 

 

Adding Water 

To utilise the full potential of the cool mode of your portable 
air-conditioner, we recommend approx 1000mls of water be 
added to the water injection port just prior to initial start up.  

To add water (see Figure 7.): 

1.  Take out the filter frame located at the bottom of the 

back of the unit. 

2.  Use a water cup to pour water into the water tray. 

Do not pour more than 1000ml. Do not overfill the 
unit. 

3.  Put back the filter frame into the unit.  

Normally an adequate quantity of water is collected to keep 
the recycling process operating. However, in high 
temperatures (over 30

0

C) or dry climates, adding water to 

commence the Aqua Chill mode will greatly assist the 
efficiency and operating temperature of the unit, but is not 
critical to the functioning of the unit. 

Please ensure that you do not over-fill the unit or the water 
tank full indicator may be triggered. 

Do not fill the water injection port while in fan mode. 

Fig. 7 

Please Note: Adding water is not a requirement for this 
unit to function normally. If you choose not to add water to this unit it will not adversely affect the 
warranty or its regular performance. 

11 

Summary of Contents for APC12

Page 1: ...PORTABLE AIR CONDITIONER APC12 APC12RC APC14...

Page 2: ...upervised or instruction concerning use of the appliance by a responsible person for their safely 7 Do not use the appliance for any other purpose than its intended use 8 The appliance must not be use...

Page 3: ...nsferring the cold from the inside to the outside through the air exhaust hose and warming the air that it returns to the room Features of your new Portable Air Conditioner No costly installation requ...

Page 4: ...Controls Electronic Remote Electronic Remote Electronic Remote Aqua Chill Pump over Pump over Pump over Water injection port Yes Yes Yes Water full alarm Yes Yes Yes Water drainage Yes Yes Yes Directi...

Page 5: ...ilter 6 Air inlet grille 7 Power cord storage and water injection port 8 Exhaust outlet adapter 9 Water drainage port 10 Removable air filter 11 Accessories 11 Flexible hose exhaust 12 Adjustable wind...

Page 6: ...al and horizontal windows However it may be necessary for you to modify some aspects of the installation procedures for certain types of windows Open the window and insert the window kit to cover the...

Page 7: ...for maximum performance This length has been designed according to the specifications of the air conditioner Do not use an extension or exchange with a different hose as that may lead to malfunction D...

Page 8: ...tor 22 High fan speed indicator Operating Instructions On Off Press ON OFF button the unit will start in AUTO mode To turn the unit off press ON OFF button again Please note The display window will sh...

Page 9: ...e Note The temperature adjustment setting is not a direct correlation to the ambient room temperature For example adjusting the setting to 180 C will not necessarily bring the ambient room temperature...

Page 10: ...in heating mode the set temperature will decrease 10 C at the end of the 1st hour and another 10 C at the end of the second hour and then maintain that temperature until switch off or manually changed...

Page 11: ...in refer to the drainage section Adding Water To utilise the full potential of the cool mode of your portable air conditioner we recommend approx 1000mls of water be added to the water injection port...

Page 12: ...that you do not move the unit around without firstly draining the internal tank If water is left in the unit then it may spill out onto the floor or carpet Continuous Drainage If you wish to operate t...

Page 13: ...l detergent 3 Rinse the filter and dry it in a shaded place 4 Push the air filter back into the original position 5 Alternatively suction the filters using a vacuum cleaner with the dusting brush atta...

Page 14: ...vated Turn the unit off wait 3 minutes until the temperature has decreased then turn the unit on again The exhaust tube is attached incorrectly or is bent Set the exhaust tube correctly as indicated i...

Reviews: