32/50
D877 MGB Rev01 HE250.docx
231 Y/N VVVF
U
Upward travel:
with VVVF driver = 1,
with microlevelling = 2,
hybrid with VVVF=3
0
3
0
232 Y/N SoftS U
Soft stop setting, if = 1 upward travel with
soft stop
0
1
1
233 OverSpeed U
Nominal speed maximum increasing
%
0
20
8
Parameter
Nr Desc. Hand term
Large Description
Unit
Setting Range
Default
Value
Note
P3 Downward Par.
DOWNWARD PARAMETERS
Min
Max
301 %AccStart D
Downward initial acceleration change rate %
0
100
1
302 Acc Dist
D
Downward accelation distance
m
0,000
10,000
1,500
303 %Acc End
D
Downward final acceleration change rate
%
0
100
100
304 HighSpeedD1
Downward high speed
m/s
0,000
2,000
0,600
305 HighSpeedD2
Second
downward
high
speed
(maintenance)
m/s
0,000
2,000
0,300 < P304
306 HighSpeedD3
Third downward high speed
m/s
0,000
2,000
0,200 < P304
307 %DecStart D
Downward initial deceleration change rate %
0
100
50
308 Dec Dist D1
Downward deceleration distance
m
0,000
10,000
0,400
309 Dec Dist D2
Second downward deceleration distance
m
0,000
10,000
0,400
310 Dec Dist D3
Third downward deceleration distance
m
0,000
10,000
0,400
311 %Dec End D
Downward final deceleration change rate %
0
100
50
312 Low Speed D
Downward low speed
m/s
0,000
0,300
0,050 < P304,P305
313 Stop Dist D
Downward stopping distance
m
0,000
10,000
0,010
314 Acc Dist DR
Downward releveling acceleration distance m
0,000
10,000
0,010
315 RelevSpeedD
Downward releveling speed
m/s
0,000
0,300
0,050 < P304, P305
316 Stop DistDR
Downward releveling stopping distance
m
0,000
10,000
0,020
317 HighSpeedD4
Fourth downward high speed
m/s
0,000
2,000
0,259 < P304
318 Dec Dist D4
Fourth downward deceleration distance
m
0,000
10,000
1,000
319 MinSpeedERS
Minimum speed for ENR stop
m/s
0,000
0,300
0,050
Parameter
Nr Desc. Hand term
Large Description
Unit
Setting Range
Default
Value
Note
P4 Advanced Par.
ADVANCED PARAMETERS
Min
Max
401 Open Time2U
Starting opening time 2
s/1000
0
20000
1000
402 Max Pos MPP
STEPPERMOTOR
maximum
opening
position
step
0
23000
13000
403 Wait Time2U
Opening waiting time 2
dec
0
30
5
404 CloseTime2U
Starting closing time 2
s/1000
0
20000
2000
406 TargetMPP U
Upward MPP opening initial position
step
0
23000
2300
<= P402
407 Open Time4U
Arrival opening time 4
s/1000
0
20000
1000
408 TargetMPP D
Downward MPP opening initial position
step
0
23000
0
<= P402
409 Wait Time4U
Opening waiting time 4
dec
0
30
10
410 CloseTime4U
Arrival closing time 4
s/1000
0
20000
2000
411 FlowMaxStop
Max dounward flow with closed MPP
lt/min
0
30
5
412 Stop Time D
Downward stopping time
s/1000
0
20000
3000
422 %SpeedIncrD
Drop test parameter increase rate
%
0
100
60
423 ZeroPos MIS
Flow meter zero position
0
50000
850