Operating instructions for
MINILIFT PUMP UNIT C40 - C50
Page: D846M5L.005
Date of Issue: 14/03/2012
Version: Rev.
02
Approved: UT
Any installation situation that is different
from the original situation proposed must be
discussed with OMARLIFT. Any situation that is not
allowed by OMARLIFT (for reasons of patents, legal,
technical or other reasons) is considered to be the
responsibility of the installing technician and may
void the warranty.
Follow these points when installing or replacing
components of the hydraulic system:
- Always bring the lift cabin to rest on the shock
absorbers;
- Make sure that the lift cannot be actuated
accidentally by switching off the master switch;
- Before opening any part of the hydraulic circuit,
removing plugs or loosening fi ttings, always
reduce oil pressure to zero.
- In the event of welding operations, prevent
waste coming into contact with oil or with the
rod and its seals and all the elastic parts of the
system;
- Eliminate the oil loss, eliminate oil leaks, maintain
the system clean at all times so that any leaks
can be easily identifi ed and eliminated.