E-7
After shooting, remove the inserted cam-
era and lens, then re-seal the empty
case and immerse it in tap water to
remove any salt as soon as possible.
5
Maintenance
For safe use of this product, always perform maintenance after each diving session.
For details, refer to “Handling After Shooting” and “Maintaining the Waterproof Function” in the PT-E series
case instruction manual. Apply the same procedures to this product.
Remove the O-rings from this product
using the provided pick for removing
O-rings. Take care not to damage the
O-rings.
Remove any foreign matter attached to
the O-ring grooves with a clean, lint-free
cloth or cotton swab. Also remove any
foreign matter from the O-ring contact
surfaces, the PT-E series case’s port
mount thread and the PPO-E04 lens
port’s O-ring groove.
After making sure that the PT-E series
case is completely dry, remove the
PPO-E04 lens port and the PER-E02
from the case.
Remove sand and dust from the O-rings.
Pinch each O-ring between your fingers
and lightly rub the entire circumference
to check for foreign matter, scratches
and cracks.
After removing foreign matter, apply the
provided grease to the O-rings and fit
them into the O-ring grooves.
To apply grease to each O-ring, squeeze
a drop of grease about the size of a
grain onto your finger and lightly rub the
entire circumference of the O-ring to
spread the grease thinly and evenly.