OLYMPUS Industrial Web Printer Operation Guide Rev.001 15/19
2. Maintenance
2.1.
Method of Test Print
2.2.
Method of the Print Head Cleaning
2.3. Remove
Jam
1) Check
the
Operation Panel
for the jam position.
2) Open
the
Side Cover
.
3) Turn levers to release two nipping roller.
4) Manually pulls loosen paper in the jam pocket.
5) Cut the paper follows the guide slit, using regular office use cutter.
6) Set the leading edge of the paper between rollers.
7) Manually rotates the nipping roller to eliminate loosen part. Make sure the paper is not slant.
8) Manually rotates the brush roller (counter clockwise looking from the front side), and remove the paper
piece if any.
9) If there are some paper piece cannot be removed by the brush roller rotation, open the brush roller unit
and remove it.
10) Close the brush roller unit.
11) Open the
Paper Exit
unit cover, and remove the paper pieces if any.
12) Close the
Paper Exit
unit cover.
13) Close the
Side Cover
.
2.4. Replacement
of the ink Cartridge
1) When yellow light of the signal tower is on, and "Ink Empty" appears on the main panel, the ink cartridge
must be replaced.
2) If the yellow light of the signal tower is on and before "Ink Empty" appears on the main panel, it is possible
to change the ink cartridge without stopping the operation.
3) When yellow light of the signal tower is on and kept running the operation, "Ink Empty" appears soon and
the unit will be stopped.
4) Approx. number of pages can be printed before "Ink Empty" error, after the yellow light turns on : 4,500
LETTER pages at 50% coverage(12.5% each color)