background image

OmniScan MX2 — Getting Started Guide

1

 

Intended Use

The OmniScan MX2 is designed to perform nondestructive inspections of industrial and commercial 
materials. Do not use the OmniScan MX2 for any purpose other than its intended use.

Instruction Manual

Before use, thoroughly review the 

OmniScan MX and MX2 User’s Manual

 and the 

OmniScan MXU 

Software User’s Manual

, and use the product as instructed. The user’s manuals contain essential 

information on how to use this Olympus product safely and effectively. Keep this guide and the user’s 
manuals in a safe and accessible location. The PDF versions of the OmniScan MX2

 User’s Manual

 and 

OmniScan MXU Software User’s Manual

 are also available on the documentation USB drive that is 

shipped with the OmniScan MX2, or can be downloaded at www.olympus-ims.com.

Safety Signal Words

Indicates an imminently hazardous situation calling attention to a procedure, practice, or the like, 
which, if not correctly performed or adhered to, could result in death or serious personal injury

Indicates a potentially hazardous situation calling attention to a procedure, practice, or the like, which, 
if not correctly performed or adhered to, could result in death or serious personal injury.

Indicates a potentially hazardous situation calling attention to a procedure, practice, or the like, which, 
if not correctly performed or adhered to, could result in minor or moderate personal injury, material 
damage, particularly to the product, destruction of part or all of the product, or loss of data.

OmniScan MX2

Getting Started Guide

Summary of Contents for OmniScan MX2

Page 1: ...also available on the documentation USB drive that is shipped with the OmniScan MX2 or can be downloaded at www olympus ims com Safety Signal Words Indicates an imminently hazardous situation calling...

Page 2: ...15 V can be present on the PA connector The warning symbol near the PA and UT connectors signals this electric shock risk Alarm and I O connector Scanner interface SVGA video output Ethernet RJ 45 por...

Page 3: ...n MX2 or an external charger approved by Olympus to charge the battery Do not recharge a battery unless the indicators light up when the capacity check button on the battery is pressed Doing so could...

Page 4: ...y requiring charging starting with the weakest battery if the recharge conditions are met The indicator for the battery being recharged flashes yellow Once the weakest battery has reached the same lev...

Page 5: ...n both batteries are used simultaneously they will both appear highlighted The OmniScan MX2 software keeps the user informed of the battery status The table below describes some of the battery status...

Page 6: ...control area alone Element Name Description Scroll knob Used to navigate through selections without the need for a keyboard mouse or touch screen Turning the scroll knob in a clockwise direction shift...

Page 7: ...message appears 2 Select Shut Down A message asking you if you want to save your setup appears 3 To save your setup select Yes You can also turn off the OmniScan MX2 by pressing and holding the Power...

Page 8: ...olland Hitech50 which contains 50 post consumer fiber DMTA 20019 01EN Rev B February 2013 DMTA 20019 01EN 50 OmniScan MX2 Getting Started Guide Adaptors The figure below shows how the OmniScan MX2 can...