2/3 inch CCD

1/2 inch CCD

Projection area

10

9

[ Fluorescence illuminator/IX2-RFA ]

Straight type illuminator designed for
maximum throughput is 20% brighter than
the previous model. Well suited for
applications requiring high intensity
excitation or multiple excitation filters. 
The field stop (FS) is built in.

[ L-shaped fluorescence illuminator/IX2-RFAL ]

Provides easy access to burner centration
and removable aperture and field stops.
The L-shaped design maintains access to
both back frame ports.

Bright excitation illumination for cell observation/manipulation

The Olympus lineup for fluorescence illumination equipment meets a wide variety of needs
including multi-color fluorescence, ratio imaging, photobleaching and uncaging observa-
tions. The brightness at low magnification is greatly improved. 

A wide range of accessories to enable different kinds of
fluorescence imaging.

[ Pinhole field stop/IX2-RFSPOT ]

Flexible field stop options IX2-RFSPOT pinhole field stop module
can be mounted in the L-shaped illuminator for photobleaching
experiments.  

*Use commercially available pinhole plate

[ Rectangular field stop/U-RFSS ]

This unique field stop allows the user to control the area of
fluorescence excitation anywhere inside the visual field. For
example, photobleaching and phototoxicity can now be limited to
only the area that is being imaged by the CCD improving overall
brightness and cell viability over long term observations. The unit is
attached at the field stop position of the fluorescence illuminator
IX2-RFAL.

[ Double lamp housing adapter/U-DULHA ]

Allows simultaneous attachment of two light
sources such as halogen and mercury.
Selection mirror
is replaceable
for custom
applications.

Fluorescence illumination light source

Reflected light fluorescence illuminators

Illumination modular units

Configuration example

New FL system

Unnecessary exposure area
caused by a round field stop

[ Double lamphouse illuminator/IX2-RFAW ]

Two light sources can be used
simultaneously, so that light stimulation can
be performed during observation.

Lamp housings

Shape

Model

Aspherical*

1

Apochromatic*

2

Average

Lamp

IR

optics

lens 

lamp life

centering

illumination

100 W mercury apo

lamp housing/

300 h

Required

Good

U-LH100HGAPO

100 W mercury

lamp housing/

300 h

Required

Good

U-LH100HG

75 W xenon apo

lamp housing/ 

200 h

Required

Excellent

U-LH75XEAPO*

3

*1: Can collect light more efficiently than conventional aspherical optics.
*2: Even illumination and no lamp focusing shift, even when changing excitation light wavelengths. 
*3: Suitable for multi-color staining or ratio imaging because of flat light source spectrum.

[ C mount camera adapters/U-TV0.35XC-2, U-TV0.5XC-3, 
U-TV0.63XC, U-TV1X-2 , U-TV1XC]

These low-magnification camera adapters cover from visible light to
near infrared red wavelength spectrum. U-TV0.35XC-2, 
U-TV0.5XC-3, U-TV0.63XC and U-TV1X-2 are attached to the left
side port.

IR camera adapters

Practical field of view (mm) =

Projection area (Field Number)

Objective magnifications

2/3 inch CCD

1/2 inch CCD

1/3 inch CCD

U-TV0.35XC-2

0.35X

22

17.1

U-TV0.5XC-3

0.5X

22

16

12

U-TV0.63XC

0.63X

17.5

12.7

9.5

U-TV1X-2

1X

11

8

6

U-TV1XC

1X

11

8

6

Camera adapter

(Projection lens)

Projection

magnifications

Projection area (F.N.)

U-TV0.63

×

C

U-TV0.35

×

C-2

U-TV0.5

×

C-3

U-TV1

×

C

U-TV1

×

-2+

U-CMAD3

Summary of Contents for IX71

Page 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Page 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Page 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Page 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Page 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Page 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Page 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Page 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Page 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Page 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Page 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Page 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Page 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Page 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Page 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Page 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...

Reviews: