background image

30

29

IX71/IX81 SYSTEM DIAGRAM

1

2

A B C D

4

Stages

Illumination pillars, condensers

Fluorescence 
illuminators

Observation tubes, 
eyepieces

3

1

2

A B C D

Camera adapters, camera ports

E

4

Stages

Illumination pillars, condensers

Fluorescence 
illuminators

Observation tubes, 
eyepieces

3

A

C

E

D

D

D

E

F

D

C

B D

A B

2

1

G

A

A

F

G

G

3

3

3

4

4

4

5

2

2

1

1

5

H

H

E

CO2

IX-ATU

Intermediate tube

U-BI90

Binocular tube

U-BI90CT

Binocular tube with 
centering telescope

GX-SPU

Side port 
intermediate tube

U-TVZ

Zoom camera 
port tube 

U-TV1X-2

Primary image 
camera port tube 

U-TV0.5XC-3

C-mount camera 
port tube with 
0.5x lens

U-TV0.63XC

C-mount camera 
port tube with 
0.63x lens

U-TV0.35XC-2

C-mount camera 
port tube with 
0.35x lens

U-TV0.25XC

C-mount camera 
port tube with  
0.25x lens

U-CMAD3

C-mount
adapter

U-BMAD

Bayonet mount
adapter

U-FMT

F mount 
adapter

U-CMT

C-mount 
adapter

IX-TVAD

Primary image
camera port tube

U-TMAD

T mount 
adapter

U-SMAD

Sony mount
adapter

U-FWO

Motorized 
observation 
filter wheel

U-TR30H-2

Trinocular tube

U-TR30-2

Trinocular tube

U-ECA

Magnification 
changer 2x

U-ECA1.6x

Magnification 
changer 1.6x

U-CA

Magnification changer 
1x, 1.25x, 1.6x, 2x

U-EPA2

Eyepoint adjuster

U-KPA

Intermediate attachment for 
simple polarising observation

IX2-PRLBP1-2 (100%) 

▲●

100% prism unit for lower back port

IX2-PRLBP8-2 (20%/80%) 

▲●

20/80% prism unit for lower back port

IX2-MDICT

Analyzer unit for 
transmitted light

Mirror unts

U-TBI90

Tilting binocular tube

U-DPCAD

Dual port  
tube with  
C-mounts

IX2-RFACA

Motorized 
fluorescent cube

IX2-RFAC

Mirror unit turret

IX2-CA2X-2 

Intermediate magnification 
lens 2X unit

IX2-TVRAC 

■▲

Motorized bottom port 
unit with C-mount

IX2-LBPC 

▲●

Lower back port  
unit with C-mount unit

IX2-TVR 

Bottom port unit

IX-HOP

Petri dish 
holder

IX-HOT

Terasaki 
plate holder

IX-HOS

Slide glass 
holder

IX-PP24NUN

Scale for 
NUNC

TM

 plate

IX-PPM

Millimeter 
scale

IX-CLMT,
IX-CLM96

Well positioner

WHN10X
WHN10X-H

Eyepieces

IX-SVL2

Cross stage with 
short left handle

IX2-SFR

Cross stage with 
flexible right handle

IX2-SP

Plain stage

IX2-GS

Gliding stage

IX2-NPS

Nosepiece stage

IX2-RSPC-2 

◆▲

Right side port 
attachment with C-mount

IX2-GCP 

Glass stage 
insert plate

U-FMP

Mechanical stage

MIU-IBC-I, MIU-IBC-IF

CO

2

 incubator

IX-CP50

Insert plate

IX-SCL

Slide clip

Thermoplate

CK40-MVR

Mechanical stage

IX-MVR

Mechanical stage

IX-SUSP

Stage plate

Incubator

IX2-KSP

Narrow plain stage

CK2-SS

Side stage

U-SIP*

Split primary image 
camera port

Cube cassette 
for full image/
split images

*

U-IFFH

Focus handle
Interface

U-ZPCB2

Z motor control  
board

RS232C calble

U-FH

Focus handle

PC-AT

(Windows XP/Vista)

U-HSTR2

Handset

U-DULHA

Double lamp 
housing adapter

U-LH100-3

100 W halogen 
lamp housing

U-LH100L-3

100 W halogen lamp housing

U-RMT

Extension cord

U-DICTS

Shift DIC slider for
transmitted light

U-DICTHR

High resolution DIC slider for  
transmitted light

U-DICTHC

High contrast DIC slider
for transmitted light

IX2-ILL100

Transmitted 
illuminator

45LBDIF
45ND25
45ND6
43IF550W45

Filter

IX-ULWCD

Ultra long working distance condenser

IX-ADUCD

Condenser adapter

U-FWR

Motorized 
reflected 
filter wheel

U-UCD8-2

Universal condenser

U-TLO

Oil top lens

U-TLD

Dry top lens

U-TLO

Oil top lens

U-TLD

Dry top lens

IX2-MLWPO

Polarizer 
attachment

IX2-MLWCD

Mid long 
working distance condenser

IX2-DICD

Water immersion DIC condenser

IX2-TLW

Water top lens

IX2-RFAL

L-shaped fluorescence 
illuminator

IX2-RFA

Fluorescence 
illuminator

32ND6
32ND12
32ND25
32ND50

Filters

IX2-FP

Frame plate 
adapter

IX2-AN

Analyzer

IX2-AN

Analyzer

IX2-UCB2

System controller

Optical
elements

Optical
elements

Optical 
elements

Optical 
elements

IX-LWPO

Polarizer 
attachment

IX2-LWUCD

Long working distance 
universal condenser

IX71S1F-3/
IX71S8F-3

IX71 frame with 
100% prism/
IX71 frame with 
20/80% prism

IX81F-3 

■▲

IX81 frame 
without prism

IX81S1F-3 

■▲

IX81 frame 
with 100% prism

IX81-ZDC 

■▲

IX81-ZDC frame 
with 100% prism 

IX2-SHA

Motorized 
shutter

IX2-LWUCDA2

Motorized long 
working distance 
universal condenser

TH4-HS

Hand switch

TH4-100

Power supply  
unit

IX2-IFSHA

Shutter interface

U-ANT

Analyzer for 
transmitted light

U-DICT

DIC slider for 
transmitted light

IX2-DSU*

Disk scanning unit

U-RFSS

Rectangular field 
stop

IX-RFSPOT

Pinhole field stop

IX2-RFRS

Ring slit 
illumination unit  

IX2-RS40, 
IX2-RS60, 
IX2-RS100

Ring slit illumination unit  

IX2-RFAW *

Double lamphouse 
illuminator

* Not avilable in some areas

 Operation via IX2-UCB2

 To consult with local Olympus subsidiary

 Made to order product

 Not recommended for IX2-DSU combination

 Choose either prism unit for IX2-LBPC

Illustrations colored cyan shows 
motorized units.

U-CLA

Collector lens adjustment

U-LH75XEAPO

75 W xenon  apo
lamp housing

U-RFL-T

Power supply unit 
for mercury lamp

U-RX-T

Power supply unit 
for xenon lamp

U-LH100HG

100 W mercury 
lamp housing

U-LH100HGAPO

100 W mercury apo
lamp housing

B

U-TV1xC

C mount 
camera 
adapter

Summary of Contents for IX71

Page 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Page 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Page 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Page 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Page 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Page 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Page 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Page 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Page 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Page 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Page 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Page 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Page 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Page 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Page 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Page 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...

Reviews: