background image

28

27

4

5

3

431

368

690.5

308

290

135

584

394

IX71 dimensions

(unit: mm)

(unit: mm)

(unit: mm)

(unit: mm)

(unit: mm)

(unit: mm)

TH4 dimensions

IX2-UCB2 dimensions

U-HSTR2 dimensions

U-FH dimensions

Weight: 16 kg  Power consumption: 200 VA  

* Lengths with an asterisk (*) vary according to interpupilllary distance.

Weight: 20.2 kg  Power consumption: 480 VA  

* Lengths with an asterisk (*) vary according to interpupilllary distance.

Weight: 21.2 kg  Power consumption: 480 VA  

* Lengths with an asterisk (*) vary according to interpupilllary distance.

IX81 dimensions

Weight: 16.9 kg  Power consumption: 350 VA  

* Lengths with an asterisk (*) vary according to interpupilllary distance.

667

*406~471

*243~391

290

135

394

299

667

*406 

~

471

*243

~

391

290

135

299

394

14.5

75

200

120

125

30

°

64.3

48.6

38.0

91.5

50.0

75.5

4.0

70.0

35.5

82.3

28.3

54.0

146

7

°

180

105

OB

See manual

151.4

212

216

125

15

310

332 (depth)

OFF

ON

SW2

SW1

HS

RS232C

ERR

NP

Z/AF

CDT

TL

FW3

FW2

FW1

AS

RSHT

MU

RMT

IX-UBC

IX71+fluorescence illuminator combination dimensions

IX71+L-shaped fluorescence illuminator dimensions

IX81-ZDC dimensions

667

*406~471

*243~391

308

290

135

394

584

667

*406~471

*243~391

308

290

135

394

453

549

Microscope body

Revolving nosepiece

Sextuple, simple waterproof mechanism incorporated

Focus

9 mm stroke (from stage surface, 7 mm upward and 2 mm downward), coaxial coarse and fine focusing knobs (minimum fine
focus graduation: 1 µm, full rotation of fine focusing knobs: 100 µm), upper limit stopper, torque adjustment for coarse focusing

Primary image port

Lower port (standard left side port: S1F 100% or S8F 80%, or optional lower Back port selectable, 2-step light path selection), 
Upper port when built-in magnification changer 1X/1.6X is replaced (optional right side port), 
Bottom port (option)

Frontal operation

Light path selector, Transmitted light intensity control and light ON/OFF switch,  TTL Pulse control switch

Transmitted light 

100 W transmitted light 

IX2-ILL100

Pillar tilt mechanism (30° inclination angle, with vibration reducing mechanism), 

illuminator

illumination pillar

Condenser holder (with 50 mm stroke, swing-in/out mechanism), 
Field iris diaphragm adjustable, 4 filter holders (ø45 mm, t=6 mm or less)

External power supply unit

TH4-100/200

Two versions available (100 V and 200 V), Optional TH4-HS hand switch can be used, 2.2 kg weight

Observation tube

Tilting binocular tube

U-TBI90

35-85° continuous angle adjustable (eyepoint height range: 406 mm-471 mm), 
interpupillary distance adjustable between 50-76 mm, diopter adjustment function, erect image, F.N. 22

Binocular tube

U-BI90CT

Built-in focusing telescope, interpupillary distance adjustable 50-76 mm, diopter adjustment function, F.N. 22

U-BI90

Interpupillary distance adjustable 50-76 mm, diopter adjustment function, F.N. 22

Trinocular tube

U-TR30H-2+IX-ATU

3 step optical path selectable (observation : straight port = 100:0, 20:80, 0:100), 
interpupillary distance adjustable 50-76 mm, diopter adjustment function, F.N. 22

Stage

Cross stage with flexible right handle

IX2-SFR

50 mm (X) X 50 mm (Y) stroke, stage insert plate exchangeable (ø110 mm)

Cross stage with short left handle

IX-SVL2

50 mm (X) X 43 mm (Y) stroke, stage insert plate exchangeable (ø110 mm)

Plain stage

IX2-SP

232 mm (X) X 240 mm (Y) stage size, stage insert plate exchangeable (ø110 mm)

IX-MVR

Mechanical stage to be used with IX2-SP, 130 mm (X) X 85 mm (Y) stroke

Narrow plain stage

IX2-KSP

160 mm (X) X 240 mm (Y) stage size, stage insert plate exchangeable (ø110 mm)

CK40-MVR

Mechanical stage to be used with IX2-KSP, 120 mm (X) X 78 mm (Y) stroke

Gliding stage

IX2-GS

Upper circular stage 360° rotatable, 20 mm (X/Y) travel

Condenser

Long working distance universal

IX2-LWUCD

5 positions for optical devices (3 positions for ø30 mm and 2 position for ø38 mm), 
aperture iris diaphragm adjustable, N.A. 0.55 / W.D. 27 mm

Long working distance Relief Contrast

IX2-MLWCD

4 positions for optical devices (for ø50 mm, Relief Contrast optical devices rotatable), 
aperture iris diaphragm adjustable, N.A. 0.5 / W.D. 45 mm 

Ultra long working distance

IX-ULWCD

4 positions for optical devices (for ø29 mm), aperture iris diaphragm adjustable, N.A. 0.3 / W.D. 73 mm

Water immersion DIC

IX2-DICD + IX2-TLW

Single position for optical device (include two optical device holders), 
40° injection pipette or electrode insertion angle, aperture iris diaphragm adjustable, N.A. 0.9 / W.D. 3.7 mm

Eyepiece

WHN10X

High eyepoint, F.N. 22

WHN10X-H

High eyepoint, diopter adjustment function, F.N. 22

Reflected light 

Fluorescence illuminator

IX2-RFAL

L-shaped design with exchangeable F.S. and A.S. modules, two filter holder sliders (2 positions, ø32 mm, t=6 mm or less)

fluorescence unit

IX2-RFA

Straight design with field iris diaphragm, filter holder slider (2 positions, ø32 mm, t=6 mm or less)

Fluorescence cube turret

IX2-RFAC

6 positions in a rotating turret, built-in shutter

Light source

100 W Hg lamp housing and transformer, or 75 W Xe lamp housing and transformer

IX71 specifications

Microscope body

Revolving nosepiece

Sextuple motorized with objective lens retraction in PC mode, 
simple waterproof mechanism incorporated

Focus

9 mm stroke (from stage surface, 7 mm upward and 2 mm downward), fine/coarse switchable focusing knobs (minimum
graduation: 0.01 µm), objective lens escape/return buttons and return to memory position buttons (each side of microscope
frame)

Primary image port

Lower port (standard left side port: S1F 100% or S8F 80%, or optional lower Back port selectable, 2-step light path selection), 
Upper port when built-in magnification changer 1X/1.6X is replaced (optional right side port), 
Bottom port (option)

Frontal operation

Light path selector button, Transmitted light intensity control buttons and light ON/OFF switch button, Fine/Coarse focus
selector button, TTL Pulse control switch (auxiliary) buttons

Transmitted light 

100 W transmitted light 

IX2-ILL100

Pillar tilt mechanism (30° inclination angle, with vibration reducing mechanism), 

illuminator

illumination pillar

Condenser holder (with 50 mm stroke, swing-in/out mechanism), Field iris diaphragm adjustable, 
4 filter holders (ø45 mm, t=6 mm or less) 

External power supply unit

IX2-UCB2

Auto voltage selector (100 V / 200 V), RS232C interface for PC operation, IX2-BSW driver software

Observation tube

Tilting binocular tube

U-TBI90

35-85° continuous angle adjustable (eyepoint height range: 406 mm-471 mm), 
interpupillary distance adjustable between 50-76 mm, diopter adjustment function, erect image, F.N. 22 

Binocular tube

U-BI90CT

Built-in focusing telescope, interpupillary distance adjustable 50-76 mm, diopter adjustment function, F.N. 22

U-BI90

Interpupillary distance adjustable 50-76 mm, diopter adjustment function, F.N. 22

Trinocular tube

U-TR30H-2+IX-ATU

3 step optical path selectable (observation: straight port = 100:0, 20:80, 0:100), interpupillary distance adjustable 50-76 mm, 
diopter adjustment function, F.N. 22

Stage

Cross stage with flexible right handle

IX2-SFR

50 mm(X) X 50 mm(Y) stroke, stage insert plate exchangeable (ø110 mm)

Cross stage with short left handle

IX-SVL2

50 mm(X) X 43 mm(Y) stroke, stage insert plate exchangeable (ø110 mm)

Plain stage

IX2-SP

232 mm(X) X 240 mm(Y) stage size, stage insert plate exchangeable (ø110 mm)

Narrow plain stage

IX2-KSP

160 mm(X) X 240 mm(Y) stage size, stage insert plate exchangeable (ø110 mm)

CK40-MVR

Mechanical stage to be used with IX2-KSP, 120 mm (X) X 78 mm (Y) stroke

Gliding stage

IX2-GS 

Upper circular stage 360° rotatable, 20 mm(X/Y) travel

Condenser

Motorized long working 

IX2-LWUCDA2

Motorized turret with 6 position slots for optical devices (3 positions each for ø30 mm and ø38 mm), 

distance universal

aperture iris diaphragm adjustable, N.A. 0.55 / W.D. 27 mm

Long working distance Relief Contrast

IX2-MLWCD

4 positions for optical devices (for ø50 mm, Relief Contrast optical devices rotatable), aperture iris diaphragm adjustable, 
N.A. 0.5 / W.D. 45 mm

Eyepiece

WHN10X

High eyepoint, F.N. 22

WHN10X-H

High eyepoint, diopter adjustment function, F.N. 22

Reflected light 

Fluorescence illuminator

IX2-RFAL

L-shaped design with exchangeable F.S. and A.S. modules, two filter holder sliders (2 positions, ø32 mm, t=6 mm or less)

fluorescence unit

IX2-RFA

Straight design with field iris diaphragm, filter holder slider (2 positions, ø32 mm, t=6 mm or less)

Fluorescence cube turret

IX2-RFACA

Motorized turret with 6 positions, built-in shutter

Light source

100 W Hg apo lamp housing and transformer, 100 W Hg lamp housing and transformer or 
75 W Xe lamp housing and transformer

IX81 specifications

Focusing position

Dry objective

Interface between air and cover glass

Oil immersion objective

Interface between sample (cultured liquid) and cover glass

Offset method

Controlled by software

Compensation for shift of observation position toward the focusing plane is by Z-axis control (built into the IX81-ZDC)

Observation methods

Fluorescence /DIC: DIC cannot be used  beside gray-sensitive colors.

Dichromatic mirror IN/OUT method for AF laser introduction

Manual exchange

F.N. limitation

Light volume is low at the image perimeter for F.N. 22 when using 2X, 4X, 10X objectives

Focusing speed

Within approx. 0.8 seconds (average) from near focusing position) 

Speed also varies according to the start position of auto focusing, and 

(not including offset time through software

individual PC performance

Focusing accuracy

±0.3 µm (when environmental temperature change is within 5°C)

Laser safety standard

Class 1 (JISC6802, IEC825, CDRH)

Laser safety function

Front monitor method (Laser light volume by special PD)

IEC60825

Camera port

Left side port

Can only be combined with U-TV1X-2+U-CMAD3, U-DPCAD, U-SIP (primary image , 1X)

Observation tube

IX-ATU+U-TR30H-2+IX-TVAD+U-CMT
IX-ATU+U-TR30-2+U-TV1X-2+U-CMAD3

IX81-ZDC specifications

Summary of Contents for IX71

Page 1: ...Laboratory for genomic Reprogramming Head of Laboratory Riken Kobe Institute Center for Developmental Biology CDB P13 Yuji Abe M D Ph D The 1st Department of Obstetrics Gynecology School of Medicine...

Page 2: ...wavelength range and flat high transmittance this new system sets a new world standard of fluorescence performance efficiently detecting even faint fluorescence signals without damaging the cell optim...

Page 3: ...lar transmission in the near infrared range is significantly enhanced Overall performance all across the wavelength range is ideally suited for today s most demanding research applications High N A ob...

Page 4: ...put output of a parallel pencil of rays and the multiple port structure for gaining the primary image are designed internally in the form of tiers To maximize the possible wavelength width the optical...

Page 5: ...filter wheels on the excitation and emission sides However this kind of mirror encounters the problem that each fluorescence image gets darker as the number of color dyes increase because the transmi...

Page 6: ...g adapter U DULHA Allows simultaneous attachment of two light sources such as halogen and mercury Selection mirror is replaceable for custom applications Fluorescence illumination light source Reflect...

Page 7: ...DICT U DICTS Thin specimen Big shearing value Thick specimen Small shearing value 10X 40X 100X U DICTHC for superior contrast with thin specimen observation U DICTHR for superior resolution with thic...

Page 8: ...s DIC optical elements for IX2 MLWCD and applicable objectives 1 Objective with compensation for 1 mm plastic dish plus 0 5 mm thick thermoplate 2 Objective with compensation ring for 0 2 mm thick cov...

Page 9: ...ffers different magnification without switching the objective lens 1 6X is standard IX71 81 and 2 0X is optional In addition to maximizing rigidity of IX2 microscope frame Olympus simplified or shorte...

Page 10: ...pen close and camera vs visual observation Parfocal compensation function among objectives This function allows the focus point to be matched from low to high magnification objectives Refocusing each...

Page 11: ...e cell injection Built in stage warming plate Objective heater 5 CO2 supply tube with 4 outer diameter 2 inner diameter and 400 mm length Not available in some areas Thermoplate MATS series This therm...

Page 12: ...llumination with twin scanners TIRFM Total Internal Reflection Fluorescence Microscopy Since 1997 Olympus has been a market leader in objective based Total Internal Reflection microscope that allows a...

Page 13: ...system from an arc lamp source ARC EVA SYSTEM DIAGRAM Main specifications Microscope Research inverted system microscope IX71 Fluorescence Arc illumination total internal reflection illuminator fluor...

Page 14: ...order Easy system upgrade by attaching double lamphouse illuminator IX2 RFAW to IX2 series inverted microscope Photoactivation illuminator for inverted microscopy The novel Kaede gene is useful in bi...

Page 15: ...urret IX2 RFAC 6 positions in a rotating turret built in shutter Light source 100 W Hg lamp housing and transformer or 75 W Xe lamp housing and transformer IX71 specifications Microscope body Revolvin...

Page 16: ...tage IX SUSP Stage plate Incubator IX2 KSP Narrow plain stage CK2 SS Side stage U SIP Split primary image camera port Cube cassette for full image split images U IFFH Focus handle Interface U ZPCB2 Z...