Cash Register CM 980-SF / 980-F / 960-SF / 962-SF
Olympia 2012
Page 97
All Rights Reserved!
6.24
Programming RS 232 ports
The cash register is equipped with 5 ports on the rear side with which to connect periphery devices (see Chapter 1).
The RS 232 serial port on the cash register serves to connect a kitchen printer or a set of scales.
6.24.1 Programmable
contents
and their status numbers
Status number 1
Device for connection
Status code 1
Kitchen printer, 58 mm (Epson)
1
Kitchen printer Olympia TH 200 80mm (Epson)
2
Reserved 3
Status number 2
Baud rate
Status code 1 Data length
Status code 2
4800
0
7 bit
0
9600
1
8 bit
1
19200
2
38400
3
Status number 3
Parity
Status code 1 Stop bits
Status code 2
None
0
1 stop bit
0
Odd
1
2 stop bits
1
Even
2