Page. 4 from 4
message B.
In order to record a new message, we
select or respectively and press
. After a message is successfully
recorded, the message is replayed
o n c e . I n o r d e r t o l i s t e n t o t h e
messages, we must use the earphone
included with the package, that is
connected as shown in figure 1.
Tone or Pulse dialling selection
I n t h i s m e n u w e c a n s e l e c t t h e
preferred dialling method. When is
selected the device is set to pulse
dialling, and when
is selected the
device is set to tone dialling. By default
this is set to Tone Dialling. Select pulse
dialling only if tone dialling is not
supported by your phone line or the line
is ISDN type.
Alarm operation setting
Selecting and we can configure
the settings referred to the operation of
the device when triggered from input A
or B.
If we select and then all the
s t o r e d n u m b e r s w i l l b e d i a l l e d
sequentially for as many times as the
pre-adjusted (2,3,4 etc). In the end of
the alarm the device starts dialling the
stored numbers for one time.
If we select and
then in alarm
condition and after the end of it , the
d e v i c e s t a r t s d i a l l i n g t h e s t o r e d
numbers for one time. If the alarm
c o n t i n u e s
t h e n
t h e
d e v i c e
i s
contiguously dialling all the stored
numbers.
If we select and , then the
device is dialling the stored numbers
for one time only, even when the alarm
condition continues.
The factory default setting for
dialler is set to .
Re-Dial Setting
We can set how many times every
number will be dialled. This can be
done by selecting and , and then
with
from to and . The
factory default setting is .
Message re-play setting
We can set how many times a message
will be played in each call. This can be
done by selecting and , and then
with
From to and . The factory
default setting is .
Setting the access code
We can change the 4 digit access code
from the factory default , and set
the preferred one. From the main menu
we select
and
. Then with
and we set each digit of the new
access code.
Exiting the main menu
By selecting and the device
exits the main menu and gets in idle
mode.
Resetting access code
If we want to set the access code back
to factory setting( ) we have to
remove the power from the dialer, and
then place the jumper on pins Cn1
(image 1) located at the bottom left part
o f t h e p r i n t e d c i r c u i t b o a r d , a n d
connect the device back to power. The
display will show and after a while it
will turn off. Then the dialer will go back
to idle state with the default access
code. Then we can remove the jumper.
A
1
A
B
G
U
1
9
L
A
E
P
P
E
F
921489000_09_005
U
F
F
2
9
2
E
E
0000
H
H
0000
C