background image

Page. 2 from 4

(figure 2). From right to left these are:
 

Two terminal blocks (+ and -) used 

for powering the device. 
 

Then there are the terminal blocks 

B, -  and A that are used to trigger the 
dialer and are connected to the alarm 
or fire panel. If the dialer is triggered 
from input A, then  message A will be 
transmitted, and if triggered from input 
B, message B will be transmitted. By 
default in these terminal blocks there 
are two jumper wires. In case one of 
the two inputs is not used, then the 
appropriate jumper wire must be left as 
default.
 

On the next three terminal blocks 

the phone line is connected. On the R 
and T the phone line must be 
connected, and in the terminal with the 
sign      the power network

s earth wire 

must be connected. When the 
available phone line is ISDN, then the 
dialer is not connected directly to the 
phone line, but through the 
appropriate ISDN modem, and on the 
modem

s RJ11 output, and not on the 

RJ45 output. If there is a phone 
connected on the first RJ11 output, 
then the other RJ11 output of the 
modem may be used.
 

On the last two terminal blocks, 

labeled TEL the rest of the telephone 
sets are connected. When the dialer is 
idle then these telephone sets are 
operating normally. In case of an alarm 
the telephone sets are disabled and the 
dialer takes control of the telephone 
line.

OPERATION - PROGRAMMING

 

When powered, the device is in idle 

state, and this is indicated with a

 

blinking dash. 
 

In order to set up the device, we 

have to enter the valid access code. 

Entering the access code.

 When key

      

is pressed, the dialer shows     on 

the display. The preset access code is

            

.

By pressing       key display shows    . 
By pressing       we accept the 
selection. The display then shows    
again. By repeating the sequence of        
and        to enter all the digits of the 
access code. Then the display shows    
and we have entered the main 
programming menu.
 

The dialer exits  from the main 

menu automatically, and returns in idle 
state, if no key is pressed for about 2 
minutes. If an alarm input is triggered 

Navigation through

the menu

Enter Button 
Accepts current selection

                  Escape Button

Used for entering the settings menu 

Display

Mounting holes

Microphone

Earphone plug

Access code reset jumper

Terminal Blocks

+

     10 - 30VDC

 

-

      0V

B

      Message Â

 

trigger input

 

-

      0V

Á 

     Message A trigger input

R

     Telephone line

         

Power network earth wire

Ô

      

Telephone line

TEL

  Telephone sets 

Figure 1

-

P

0000

-

0

-

921489000_09_005

Summary of Contents for BS-489

Page 1: ...ed by the user when needed It is used to immediately call the police the fire department the owners etc in case of emergency When triggered the auto dialer dials the phone numbers stored in its memory in priority 0 9 as stored by the user The device skips the blank memory positions MOUNTING The bottom cover can be removed by unscrewing the retaining screw at the bottom side of the device For wall ...

Page 2: ... rest of the telephone sets are connected When the dialer is idle then these telephone sets are operating normally In case of an alarm the telephone sets are disabled and the dialer takes control of the telephone line OPERATION PROGRAMMING When powered the device is in idle state and this is indicated with a blinking dash In order to set up the device we have to enter the valid access code Enterin...

Page 3: ... as which stands for pause 0 8 seconds that stands for asterisk and that stands for sharp If we want to delete an existing phone number we select its priority and we replace the first digit with and press Displaying saved phone numbers We can check which number is saved in each memory position We select from the menu and press With keys we select the number s priority and we accept with Then the d...

Page 4: ...guously dialling all the stored numbers If we select and then the device is dialling the stored numbers for one time only even when the alarm condition continues The factory default setting for dialler is set to Re Dial Setting We can set how many times every number will be dialled This can be done by selecting and and then with from to and The factory default setting is Message re play setting We...