921468007_09_011
Programming passwords functions
«CODES»
«CHANGE CODE»
Through this option we can select the way that each user's pass-
word works.
We enter the number of the code that we want to alter and we see
the following screen:
For each code we must make one of the following selections
which mean:
«OFF». The password is present but does not have any function.
«NATURAL ARM DISARM». The password arms and disarms the
panel. By pressing " *
" we must select the section that the
password affects. We select A, B, C or ABC. By default all pass-
words are set for «NATURAL ARM DISARM» and for section
ABC.
«PANIC 24 HOURS». This password gives a panic alarm, no matter what is the state of the panel.
«SET». The password arms (does not disarm) the panel immediately. Making this selection and press-
ing " *
" we must select the section that is affected by the password. We can select A, B, C or ABC.
«UNSET». The password disarms (does not arm) the panel immediately. Making this selection and
pressing " *
", we must select the section that is affected by the password. We can select A, B, C or
ABC.
«SET WITH DELAY EXTRA». The password arms only (does not disarm) the panel but with an exit
delay that equals with : EXIT TIME + EXTRA EXIT TIME. Making this selection and pressing " *
",
we must select the section that is affected by the password. We can select A, B, C or ABC. The extra
delay exists either there are zones with delay either not in the same section.
«PG CONTROL». The password activates or deactivates one of the controllable outputs. Making this
selection and by pressing " *
" the user selects the output that the password affects. We can select
Ρ1, Ρ2, Ρ3 or RELAY.
«SILENT ALARM». The code activates the silent alarm. When the user enters the code, the panel will
disarm (if the panel is armed) and will remain in idle state (the siren will not sound, and the alarm leds
will be off). The panel will call or send a message via BS-465 or BS-464 to the selected telephone
numbers.
CHANGE CODE
CHOOSE FROM 01 TO 50
- -
___CODE REACTION __
OFF
NATURAL ARM DISARM
PANIC 24 HOURS
SET
UNSET
SET WITH DELAY EXTRA
PG CONTROL
SILENT ALARM