5
921468007_09_011
2. User instructions
2.1.
Basic operations
The panel has 1 main code (master code) which by default is set to [1 2 3 4] and up-to 50 user codes
which by default are not programmed. The system can operate in two different modes. Depending on
the mode of operation, the arm and disarm operations differ.
Complete System
In this case the system arms and disarms altogether.
Arming
can be achieved by using the master code or one of the user codes. The arming of the sys-
tem can also be done by simply pressing the ABC key during the installation if the option «ARM
WITHOUT CODE» has been selected.
Disarming
can be achieved by entering the master code or one of the user codes.
Split System
In this case the system operates as three independent subsystems.
You can arm and disarm the
whole system or each subsystem independent from the others.
Arming of the whole system
can be done by using the master code or one of the user codes that
have been programmed for general arming. The arming of the system can also be done by simply
pressing the ABC key if during the programming the option «ARM WITHOUT CODE» has been se-
lected.
The disarming of the system
can be done by using the master code or one of the user code that
have been programmed for general disarming.
The individual arming of the subsystems
Α, Β, C
can be done by pressing one of the user codes
that have been programmed to arm each subsystem. The arming can also be done by pressing one of
the
Α, Β or C keys if during the programming « ARM WITHOUT CODE » has been selected. The arm-
ing of one subsystem does not affect the status (armed-disarmed) of the other subsystems.
The individual disarming of the subsystems
Α, Β, C
can be done by pressing one of the user
codes that have been programmed to disarm each subsystem. The arming of one subsystem does not
affect the status (armed-disarmed) of the other subsystems.
If during the arming procedure a zone is active then the keyboard shows the message:
Which means that on zone 5(kitchen) a window has been left open.
If we press (#) the arm command is canceled.
If we press (*) or close the kitchen window we see:
This message is shown for 1 second and immediately the arming
process starts.
SYSTEM CAN NOT ARM
ZONE 05
KITCHEN
*:
BYPASS ZONE
#:
CANCEL
ZONES BYPASSED
READY TO ARM