![Olivetti d-Copia 12 Service Manual Download Page 60](http://html1.mh-extra.com/html/olivetti/d-copia-12/d-copia-12_service-manual_3853741060.webp)
6-6
Service Manual
Y101700-5
Content
Main motor system ON + Cooling fan low speed
(Operation/Procedure)
When the START key is pressed, the main motor is rotated for 30 sec.
To save toner consumption, the different operations are executed depending on
installation of the developing unit.
• When the developing unit is installed, the developing bias, the main charger, and the
grid are also outputted.
• When the developing unit is not installed, only the motor is rotated.
* Do not turn on the door open/close switch forcibly to execute this simulation.
Polygon motor ON
(Operation/Procedure)
When the START key is pressed, the polygon motor is operated for 30sec.
Manual feed setup
(Operation/Procedure)
1. When this simulation is executed, the currently set bypass code number is displayed.
2. Enter the code number corresponding to the bypass and press the START key, and
the setting will bechanged.
Code number
Bypass
0
Single bypass
1
Multi bypass
SPF setup
When this simulation is executed, the currently set SPF code number is
displayed. Enter the code number of the SPF to be set and press the PRINT switch. The
setup is changed.
Code number
SPF
0
Without SPF
1
With SPF (Setup required
when installing FAX)
2
With RSPF
Second cassette setup
(Operation/Procedure)
1. When this simulation is executed, the currently set code number of the second
cassette is displayed.
2. Enter the code number and press the Start key. The setting is changed.
Code number
Second cassette
0
Without second cassette
1
With second cassette
Main code
25
26
Sub code
01
10
01
02
03