![Oliver 711 User'S Operating And Instruction Manual Download Page 10](http://html1.mh-extra.com/html/oliver/711/711_users-operating-and-instruction-manual_3791077010.webp)
MODEL 711 COUNTER TOP SLICER
0711S20005-
1
MAINTENANCE
WARNING
ALWAYS UNPLUG THE SLICER BEFORE PERFORMING ANY TYPE
OF MAINTENANCE TASK.
REMOVING BLADE FRAMES
Remove the top guard and front guard by removing the twelve slotted head screws
which hold them in place. See the illustration on the next page.
In addition to the above, the infeed table must be removed to allow removal of the
lower blade frame. This can be done by removing the two slotted head screws
securing it and pulling the table down out of the clips and out through the infeed
opening. See the illustration on the next page.
NOTE
Removal of the lower blade frame is not required to change its blades.
Pull the clip from the eccentric pin and slide the link toward the eccentric pin mounting
plate. See the illustration below.
Rev. 11-30-00