9
H
eat
D
etector
tI 150
Installation Without an Alarm System
Connecting heat detectors without an alarm system
The heat detectors can be connected to each other directly via radio signals. This ensures
that, in the event an alarm is triggered, all the heat detectors connected issue an alarm
signal. We recommend connecting the heat detectors to each other before assembling
the heat detectors.
Warning
! Hearing damage through loud alarm signal! The
alarm signal is loud and could cause hearing damage. Do
not test the product close to your ears. Use appropriate ear
protectors when connecting the heat detectors.
1
Insert two appropriate batteries in the battery compartments of all the heat detectors
to be installed. Pay attention that the batteries are inserted the right way around.
2
Press the Test button (5) on one of the heat detectors (main device) three times in succes-
sion.
3
The signal LED (4) lights up continuously. The main device is ready for connection.
4
Press the Test button (5) on one of the other heat detectors three times in succession.
5
An acoustic alert signal is issued and the heat detector is connected to the main device.
6
(Option:) Repeat the connection process for all the heat detectors to be connected.