Remote acknowledgment 

through  short  circuit  of  2  MX15  terminals,  using  an 
external potential-free dry contact (maximum 2 meters)  

 
Certification 
 
ATEX 94/9/CE Directive: 

category  (3)G  for  metrology  in  explosive  gas  detection  EN 
61779-1 and 4 in zones 2. 

 
Low-voltage directive:  

in accordance with EN 61010 

 
Electromagnetic Compatibility  
Directive CEM: 

in accordance with EN 50270  

 

I

I

I

I

I

I

.

.

 

 

D

D

e

e

t

t

a

a

i

i

l

l

 

 

s

s

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

 

 

f

f

o

o

r

r

 

 

u

u

s

s

e

e

 

 

i

i

n

n

 

 

E

E

x

x

p

p

l

l

o

o

s

s

i

i

v

v

e

e

 

 

A

A

t

t

m

m

o

o

s

s

p

p

h

h

e

e

r

r

e

e

s

s

 

 

i

i

n

n

 

 

a

a

c

c

c

c

o

o

r

r

d

d

a

a

n

n

c

c

e

e

 

 

w

w

i

i

t

t

h

h

 

 

t

t

h

h

e

e

 

 

A

A

T

T

E

E

X

X

 

 

9

9

4

4

/

/

9

9

/

/

C

C

E

E

 

 

E

E

u

u

r

r

o

o

p

p

e

e

a

a

n

n

 

 

D

D

i

i

r

r

e

e

c

c

t

t

i

i

v

v

e

e

 

 

 

The MX15 detection central unit, designed for measurement of explosive gas, is compliant 

with the requirements of the ATEX 94/9/CE European Directive regarding explosive atmospheres. 
 

Thanks  to  its  metrological  performance,  the  MX15  central  unit  associated  with  the 

INDUSTRIAL  SCIENTIFIC  CEX300  and  OLC  10  detectors  is  a  safety  device  for  ATEX  Zone  2 
classified areas.  The central unit can also reduce the risk of explosion through information provided 
to external units. 
 

The  site  manager  where  the  equipment  is  installed  should  take  into  consideration  and 

comply  with  the  information  in  the  following  paragraphs.    Refer  to  the  provisions  of  the  ATEX 
1999/92/CE  European  Directive  regarding  the  enhancement  of  safety  and  health  of  the  workers 
exposed to risks of explosive atmospheres. 
 

1

1

.

.

 

 

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

 

 

f

f

o

o

r

r

 

 

m

m

e

e

c

c

h

h

a

a

n

n

i

i

c

c

a

a

l

l

 

 

a

a

n

n

d

d

 

 

e

e

l

l

e

e

c

c

t

t

r

r

i

i

c

c

a

a

l

l

 

 

i

i

n

n

s

s

t

t

a

a

l

l

l

l

a

a

t

t

i

i

o

o

n

n

 

 

i

i

n

n

 

 

C

C

l

l

a

a

s

s

s

s

i

i

f

f

i

i

e

e

d

d

 

 

Z

Z

o

o

n

n

e

e

 

 

 

Installation  will  be  performed  in  accordance  with  existing  standards,  in  particular,  EN 

60079-14, EN 60079-17 standards. 

 
The  MX15  central  unit  should  not  be  exposed  to  mechanical  vibrations  and  should  be 

installed in a safe area, away from explosive atmospheres. 

 

It  is  essential  to  refer  to  the  operating  and  start-up  instructions  of  the  above-mentioned  gas 

detectors in paragraph ‘Detail specifications for use in explosive atmospheres in accordance with the 
ATEX 94/9/CE European Directive.’ 

 

 

2

2

.

.

 

 

M

M

e

e

t

t

r

r

o

o

l

l

o

o

g

g

i

i

c

c

a

a

l

l

 

 

S

S

p

p

e

e

c

c

i

i

f

f

i

i

c

c

a

a

t

t

i

i

o

o

n

n

s

s

 

 

 

 

The  central  unit  complies  with  the  metrological  European  standards  EN61779  and 

EN61779-4  for  methane  (calibration  gas),  butane,  propane  and  hydrogen  (gas  as  per  response 
curves), when the central unit is used with CEX300 and OLC 10 gas detectors. 

Summary of Contents for MX15

Page 1: ...I IN NS ST TA AL LL LA AT TI IO ON N A AN ND D O OP PE ER RA AT TI IN NG G I IN NS ST TR RU UC CT TI IO ON NS S Ref NPM15GB...

Page 2: ...uired particularly for electrical installation and assembly connections service lines Any modification of the equipment as well as use of unauthorized parts will result in cancellation of any warranty...

Page 3: ...ECIFIC USE C C L L A A U U S S E E S S C C O O N N C C E E R R N N I I N N G G P P R R O O P P E E R R T T Y Y Drawings plans specifications and information included in this document contain confident...

Page 4: ...ly 230 Volts 115VAC on request 11 2 2 2 Power supply 24 VDC protection through F8 can be connected on terminals 0 and 24V as indicated in the wiring examples at the end of the manual 11 2 3 Measuring...

Page 5: ...otentiometers A motherboard including all system components power supply display relays and connectors A front face with tactile keys I I I I T T e e c c h h n n i i c c a a l l s s p p e e c c i i f...

Page 6: ...ammable Display front Type LCD screen 4 digits 7 segments 3 characters 14 icon segments 4 LEDs Description of unit and gas programmable by user in a list 3 characters edited by user Keyboard through t...

Page 7: ...h information provided to external units The site manager where the equipment is installed should take into consideration and comply with the information in the following paragraphs Refer to the provi...

Page 8: ...l unit in configuration 0 at 100 LEL The following curve provides a response to the central unit regarding the measured value and fault processing based on the value of the input current supplied by t...

Page 9: ...n attended area control centre console room control room etc and in a less humid no condensation and temperate environment see chapters 2 1 and 3 2 2 C Ce en nt tr ra al l u un ni it t e el le ec ct t...

Page 10: ...should be wired on the two terminals L orange and N blue as indicated in the wiring examples at the end of manual 2 2 2 Power supply 24 VDC protection through F8 can be connected on terminals 0 and 2...

Page 11: ...e in positive safety negative upon request and potential free REL1 terminals match the relay 1 contacts alarm 1 REL2 terminals match the relay 2 contacts alarm 2 The relay contacts can be used normall...

Page 12: ...replaced with an interrupted line on the display unit To return to the measurement display press one of the two keys or To return to normal operation simultaneously press the and keys 2 2 M Me en nu u...

Page 13: ...larms 1 manual MAN if the gas concentration again becomes lower than the preset alarm threshold this alarm must be acknowledged manually by pressing the acknowledgment key 2 or automatical AUT if the...

Page 14: ...changes the access code for various menus 1000 in standard upon shipment of equipment display the CODE menu and key validate it enter display current code indicate the new code using the and keys vali...

Page 15: ...s concentration is correct by reading the display unit Otherwise adjust the sensitivity using a S potentiometer Disconnect the standard gas cylinder Wait for the return to zero on the display unit Pre...

Page 16: ...intended to be a measure of the accuracy of the instrument Industrial scientific further recommends that a full instrument calibration be performed using a certified concentration s of calibration ga...

Page 17: ...onal use of natural resources MX15 has to be the object of a selective collection for the electronic equipments and cannot be scrapped with the normal domestic waste The user thus has the obligation t...

Page 18: ...gment 1 3 relay contact outputs potential free NO or NF based on position of jumpers next to relays DEF RL1 RL2 Connector of first sensor with 2 wires Example of connection between a MX15 central unit...

Page 19: ...0 TWIN type sensors L N T MAINS 230VAC 0 24V Remote acknowledgment 1 2 3 Connector of first sensor with 3 active wires relay contact outputs potential free NO or NF based on position of jumpers next t...

Page 20: ...ring 1 2 3 1 2 3 Example of connection with an EXPLO or TOXIC sensor with 3 active wires L N T MAINS 230VAC 0 24V relay contact outputs potential free NO or NF based on position of jumpers next to rel...

Page 21: ...22...

Page 22: ...23 Ex Ox Tox Gasdetectie Westerdreef 5V 2152 CS Nieuw Vennep Telefoon 0252 620885 E mail info exoxtox n Website www exoxtox nl...

Reviews: