Use of equipment:- 

 

The user must ensure that the lamp supplied meets the safety standard required for the Zoned 

area:- 

 

1.  This equipment must only be used in a Category M2 zone without undertaking a full risk 

assessment for mine rescue use. 

  

2.  Check that the operating temperature range is in the range 0

o

C to +40

o

C for Mining. 

 

3.  The lamp must not be disassembled in a hazardous area. 

 

4.  The lamp must not be charged in a hazardous area. 

 

5.  The battery casings are manufactured from polycarbonate and ABS with nitrile rubber 

seals.  The performance of these materials, with respect to attack by aggressive 

substances that may be present in the hazardous area, shall be taken into account before 

the equipment is used. 

 

6.  Plastic surfaces may cause propagating brush discharges.  Propagating brush discharges 

are caused by non-conducting fluid flow over a non-conducting plastic surface.  The cap 

lights shall not be used in areas where a high fluid flow over the plastic surfaces may occur 

(for example in the case of a ruptured process pipe or compressed air pipe). 

 

Special Conditions for Safe Use: 

 

There are no special conditions stipulated within the certification. 

 

 

Denchi Power Ltd. 

Denchi House, Thurso Business Park, 

Thurso, Caithness, KW147XW 

 

 

URL:   www.oldhamcaplamps.com 

Email: [email protected] 

Tel.: +44 (0)1847 808000

 

 

 

August 2016 

 

 

Summary of Contents for DL9

Page 1: ...rform as designed only if used and maintained according to the instructions otherwise it could fail to perform as designed and persons who rely on this product could sustain serious personal injury or...

Page 2: ...from battery p4 Replacing battery cover p4 Using DL9 DL16 cap lamp systems p4 Repairing headpiece p4 Replacing cable p5 Replacing reflector p5 Replacing circuit board p5 Reassembling bezel ring p6 Re...

Page 3: ...use fitted terminal nuts and washers Remove the nut and washer from the positive end of the fuse marked Place the ring terminal of the red wire onto the terminal post replace the spring washer and nut...

Page 4: ...d 4 Remove the fuse 5 Remove the negative lead black Replacing battery cover 1 Replace the fuse fit the nuts to hold the fuse in place 2 Connect the red cable to the positive battery terminal 3 Connec...

Page 5: ...flector is located by two projections which fit either side of the main LED the hole in the reflector goes over the secondary LED The bezel ring should be screwed down firmly while holding the glass d...

Page 6: ...m head screw Replacing the lock barrel If the lock barrel is damaged it may become difficult to connect the lamp to the charger In this case the lock barrel must be replaced M259983 lock contact spare...

Page 7: ...3 D and G Cable Terminal Spares kit 201520 M204683 D and G Lock Contact Spares kit 201521 M204783 D and G Cap clip Spares kit 201545 M455045 Plastic Battery Cover complete Clip for standard cover Scre...

Page 8: ...8...

Page 9: ...flickers or dims when any of the preceding items are being checked that item should be repaired or replaced Battery appears dead and will not operate a Check that the fuse has not blown b Check the cr...

Page 10: ...IEC62013 1 Ta 0o C to 40o C IECEx ITS 08 0019 Ex I Ta 0o C to 40o C Type DPL9 DPL16 Lamp Type Reference The lamps can be assembled in a variety of combinations to satisfy customer requirements The ass...

Page 11: ...with respect to attack by aggressive substances that may be present in the hazardous area shall be taken into account before the equipment is used 6 Plastic surfaces may cause propagating brush disch...