background image

IMPORTANT NOTE: 

The L16 battery is supplied with a factory fitted 

“OCBL-T” fuse (M455323), required for 

protection of the internal battery circuitry.  

Use of any other fuse type could result in 

damage and will invalidate any warranty claim.

 

IMPORTANT 

 

Pay close  attention  to Warnings and Cautions in 

this manual.  

A WARNING describes a condition that may cause 

severe  personal  injury  or  death  if  allowed  to 

happen.  

A CAUTION describes a condition that may cause 

moderate injury or property damage if allowed to 

happen. 

 

GENERAL DESCRIPTION 

 

The GL9/GL16 cap lamp systems consists of a cap 

mounted headpiece powered by a Li Ion battery. 

 

The basis of the headpiece in which some of the 

internal connections are integral is as follows: 

A selector switch is incorporated, which can switch 

on  either  the  large  main  bulb  or  the  small 

secondary  bulb.  The  main  bulb  is  held  in  the 

reflector in a focused position by a screwed bush 

from  which  a  lead  connects  to  one  of  the  cable 

termination  points.    The  small  bulb  holder  is 

positioned  at  the  top  of  the  headpiece,  being 

connected internally to the cable termination. The 

reflector fits over the small bulb and has a rubber 

gasket  around  the  rim  to  seal  against  the 

headpiece lens. 

 

PREPARING THE GL9 or GL16 CAP LAMP FOR 

FIRST TIME USE 

 

The battery is packaged separately to the lamptop 

and needs to be connected before use. 

 

Tool kit required is M614830 

 

NOTE: THE BATTERY IS TRANSPORTED IN A 

PARTIALLY  CHARGED  CONDITION  -  EVERY 

BATTERY  MUST  BE  FULLY  CHARGED 

BEFORE FIRST USE. 

 

Remove  the  battery  from  the  shipping  box  and 

check for damage.  The battery is supplied with the 

encapsulated  fuse  fitted,  terminal  nuts  and 

washers. 

 

Remove the nut and washer from the positive end 

of the fuse ().  Place the ring terminal of 

the  red  wire  onto  the  terminal  post,  replace  the 

spring washer and nut, and tighten to 0.5Nm. 

 

Remove  the  nut  and  washer  from  the  negative 

terminal (not connected to the fuse) and place the 

ring  terminal  of  the  black  wire  onto  the  terminal 

post,  replace  the  spring  washer  and  nut,  and 

tighten down to 0.5Nm. 

 

 

 

Hook the cable exit end of the battery cover onto 

the battery.   

 

Check that the cables are not trapped  under the 

edge of the cover then press down into position. 

 

Secure  the  cover  in  place  with  the  clip  and  M4 

mushroom head socket screw. 

 

  

 

 

 

Battery charging 

 

WARNING 

 

Li  Ion  batteries  must  only  be  charged  on  a 

specific charger with a Li Ion charge profile.  If 

the  battery  is  charged  on  a  standard  GT 

caplamp charger the battery will be damaged.   

 

For  charger  information  and  how  to  convert 

existing  charger  software  please  consult  the 

Caplamp Charger Manual. 

 

Every battery must be charged before it is used for 

the first time. 

 

Never discharge completely! 

 

Summary of Contents for Denchi Power GL9

Page 1: ...on service or repair This cap lamp system will perform as designed only if used and maintained according to the instructions otherwise it could fail to perform as designed and persons who rely on this...

Page 2: ...airing the headpiece p5 Replacing bulbs p5 Removing the bezel ring p5 Replacing main bulb p5 Replacing secondary bulb p5 Replacing the reflector p6 Replacing the cable p6 Reassembling the bezel ring p...

Page 3: ...MP FOR FIRST TIME USE The battery is packaged separately to the lamptop and needs to be connected before use Tool kit required is M614830 NOTE THE BATTERY IS TRANSPORTED IN A PARTIALLY CHARGED CONDITI...

Page 4: ...n 2 Un clip the clamp and slide off the cover to cable end 3 Remove the positive cable lead red 4 Remove the fuse 5 Remove the negative lead black Replacing battery cover 1 Replace the fuse fit the nu...

Page 5: ...tight so that no electrical resistance is incurred which might increase the time necessary to obtain an efficient charge or possibly reduce the light output of the lamp In order to obtain the maximum...

Page 6: ...battery cover and gently pull the cable out of the battery cover gland 3 Unscrew the battery collar cable outlet gland from the headpiece 4 Remove the bezel ring see removing the bezel ring and glass...

Page 7: ...d remove the dome head screw that runs through the charging contact housing 2 The metal cap clip can be lifted off and set to one side take care not to lose the spring clip 3 Remove the lock barrel an...

Page 8: ...washer Charging contact screw Large bulb socket block Large bulb socket screw 201524 M205083 Cable Terminal Spares Kit D and G type Cable grip Sealing collar Small terminal tag Large terminal tag Ter...

Page 9: ...9...

Page 10: ...en any of the preceding items are being checked that item should be repaired or replaced Battery appears dead and will not operate a Check that the fuse has not blown b Check the cross volts of the ba...

Page 11: ...p Classification B2 201500 M259130 Prefocus Halogen 4 1v48L T2 B2 not available M259530 Prefocus Halogen 4v 1 5A T2 B3 201528 M259230 Prefocus Halogen 4v 0 75A T3 B4 201511 M201230 Prefocus Krypton 4v...

Page 12: ...rubber seals The performance of these materials with respect to attack by aggressive substances that may be present in the hazardous area shall be taken into account before the equipment is used 7 Pl...

Reviews: