Variant 2 above ground line routing
•
For above-ground piping, install a protective pipe with at least
Ø
DN160 and
bends with max. 45°.
•
Install the wall duct by means of a pipe duct and a lining pipe (to be provided in
the concrete formwork).
•
Check with the builder or an expert to determine the appropriate penetration for
a brick wall.
•
Attach the DN160 wall bracket (accessory) on the outside and lay the protective
pipe with 45° bends up to the outer tank.
•
At the tank there is an insertion nozzle on which the hoses as well as the adapter
for the protective tube can be mounted.
Grounding/potential equalization
•
Grounding of the filling nozzle:
Observe the country-specific regulations.
8
3 Planning Pellet Outside Storage
Installation manual