Page: 57
Service Guide ML393/ML393CPlus
Chapter 3 Maintenance
3.2.05 Operator Panel Assembly
1. Remove the upper cover assembly
(3.2.04
).
2. Disconnect the operator panel cable (1) from CN10 (2) on the control board.
3. Remove the two mounting screws (3).
4. Detach the operator panel holder (4) by moving it upward, and then pulling toward the front of the
printer.
5. Remove the three mounting screws (5).
6. Open the eleven claws and detach the operator panel (6) from the operator panel holder.
P/N 55050601 PCB: Operator Panel (LQSX) RSPL B.2.05
P/N 53479103 Panel: Operator RSPL B.2.05
P/N 56614608 Cable: Operator Panel RSPL B.2.05
P/N 50910505 Spring: Cover Open RSPL B.2.05
P/N 56614301 Cable: Microswitch (Cover Open) RSPL B.2.05
P/N 53535301 Lever: Cover Open B.2.05