![background image](http://html1.mh-extra.com/html/okidata/ml393plus/ml393plus_service-manual_3659277100.webp)
Page: 66
Service Guide ML393/ML393CPlus
Chapter 3 Maintenance
3.2.14 Space Motor Assembly
1. Remove the printhead
(3.2.01
).
2. Remove the upper cover assembly
(3.2.04
).
3. Remove the ribbon feed assembly
(3.2.13
).
4. Loosen the two belt pulley bracket mounting screws (1).
5. While pushing the belt pulley bracket (2) to the left, temporarily tighten the two screws. This will ease
the tension on the space belt.
6. Remove the three space motor mounting screws (3).
7. Remove the space motor (4) by pulling it toward the front of the printer.
NOTE:
Perform the printhead gap adjustment after installation. Refer to Section 3.3 of this Service Handbook for
further information.
P/N 56506201 Motor: Space Assembly RSPL B.2.06
, B.2.09