![OKIDATA ML1120 Maintenance Manual Download Page 35](http://html1.mh-extra.com/html/okidata/ml1120/ml1120_maintenance-manual_729916035.webp)
43471801TH Rev.1
35 /
Oki Data CONFIDENTIAL
3.3.4 Upper Cover Assy, Access Cover Assy and Sheet Guide Assy
(1)
Pull off the platen knob
1
.
(2)
Turn the change lever toward the top position.
(3)
Remove the sheet guide Assy
2
.
(4)
Remove the tractor Assy
3
.
(5)
Remove the pull-up Assy
4
.
(6)
Remove the two screws
5
in the rear.
(7)
Detach the claw (A) at the rear of the upper cover
6
.
(8)
Insert a flat-blade screwdriver into grooves (3 places (B)) of frame and twist to disengage
claws of upper cover
6
.
(9)
Raise the upper cover Assy
6
to remove.
(10) Remove the access cover Assy
7
.
(11) Assemble in the reverse order of disassembly.
Chenge lever
1
6
7
2
3
5
4
B
A