MSM80C154S/83C154S/85C154HVS
120
B = f
OSC
×
65536-D
RCAP2
1
×
16
1
2
1
×
where B is the baud rate, f
OSC
the fundamental oscillator (XTAL1·2) frequency, and D
RCAP2
the contents of R
CAP2L
and R
CAP2H
(expressed in decimal).
4.6.3.4.3 Mode 3 transmit operation
The transmit basic clock (TXCLOCK in Figure 4-36) is obtained from a hexadecimal free-run
counter overflow where timer/counter 1 or timer/counter 2 overflow is used as the clock.
Transmission is commenced when transmit data is written in SBUF.
The start bit, the eight SBUF data bits (with the LSB first), TB8, and the stop bit are transmitted
sequentially from the TXD synchronized with the basic clock.
As soon as the TB8 output has been completed, the transmit circuit is initialized, and the T1
flag is set at the first M1·S3 after the completion of that output.
4.6.3.4.4 Mode 3 receive operation
The receive circuit timing is generated by a hexadecimal counter overflow where timer/
counter 1 or timer/counter 2 overflow is used as the clock, and the input data received from
the RXD is bit synchronized. That is, at the same time that reception is started following input
of the start bit, the hexadecimal counter commences to count up, and with one complete
round of the hexadecimal counter corresponding to one bit of received data, reception is
continued by the receive circuit. Therefore, timer/counter 1 must be set so that the period of
a single round of the hexadecimal counter is equal to the reception data baud rate.
The RXD change from “1” to “0” is regarded as the beginning of the start bit where reception
is commenced.
When this “1” to “0” RXD change is detected, the hexadecimal counter which had been
stopped in reset status commences to count up. When the hexadecimal counter is in state
7, 8, and 9, the start bit is sampled, and is accepted as valid if at least two of the three sampled
values are “0”, thereby enabling data reception to continue. If two or three of the sampled
values are “1”, the start bit becomes invalid, and the receive circuit is initialized when the
hexadecimal counter reaches state 10.
The reception data is sampled when the hexadecimal counter is in state 7, 8, and 9, and the
more common value of the three sampled values is read sequentially as data into the input
shift register.
If the hexadecimal counter is in state 10 during the period of the next bit (that is, the multi-
purpose data bit) after the eight bits of data have been received, and if the conditions stated
below are satisfied, the input shift register data (the LSB being read first) is loaded into SBUF,
and the sampled multi-purpose data bit is read into RB8. And when the hexadecimal counter
is in state 10 during the period of the next after that (that is, the stop bit) the receive circuit
is initialized.
The RI flag is set at the first M1·S3 after that.
Conditions: (1) RI=“0”
(2) SM2=“0”, or SM2=“1” and sampled multi-purpose data bit=“1”
Summary of Contents for MSM85C154HVS
Page 1: ...MSM80C154S MSM83C154S MSM85C154HVS USER S MANUAL...
Page 8: ...1 INTRODUCTION...
Page 9: ...MSM80C154S 83C154S 85C154HVS 2...
Page 15: ...MSM80C154S 83C154S 85C154HVS 8...
Page 16: ...2 SYSTEM CONFIGURATION...
Page 17: ...MSM80C154S 83C154S 85C154HVS 10...
Page 48: ...3 CONTROL...
Page 49: ...MSM80C154S 83C154S 85C154HVS 42...
Page 60: ...4 INTERNAL SPECIFICATIONS...
Page 61: ...MSM80C154S 83C154S 85C154HVS 54...
Page 197: ...MSM80C154S 83C154S 85C154HVS 190 5 INPUT OUTPUT PORTS...
Page 198: ...INPUT OUTPUT PORTS 191...
Page 220: ...INPUT OUTPUT PORTS 213...
Page 221: ...MSM80C154 83C154 85C154 214 6 ELECTRICAL CHARACTERISTICS...
Page 222: ...ELECTRICAL CHARACTERISTICS 215...
Page 236: ...7 DESCRIPTION OF INSTRUCTIONS...
Page 237: ...MSM80C154S 83C154S 85C154HVS 230...