Chapter 14: Epson - Standard Functions
14-29
Function
Dec.
Hex.
ASCII
Setting of page length
27 40 67
1B 28 43
ESC (C
in basic step sizes
Ln Hn
Ln Hn
Ln Hn
Lp Hp
Lp Hp
Lp Hp
Ln = 0 to 255
Hn = 0 to 255 (MSB ignored)
Lp = 0 to 255
Hp = 0 to 255 (MSB ignored)
This command defines the page length of the currently selected pa-
per path. The parameters Ln and Hn specify the number of parame-
ters following this:
Hn = integer (number of characters / 256)
Ln = number of characters - (Hn * 256)
For this command, Hn = 0 and Ln = 2 must be set. With Ln + Hn *
256 < 2, this command is ignored. With Ln + Hn * 256 > 2, all Ln +
Hn * 256 data following Lp, Hp are ignored.
The parameters Lp and Hp define the page length in whole multi-
ples of the current basic step size:
Hp = integer (page length in basic step sizes / 256)
Lp = page length in basic step sizes - (Hp * 256)
Valid values for the basic step size are: 1/360, 1/180, 1/120, 1/90,
1/72 and 1/60 inch.
All page lengths in the range 1/360 inch to 22 inches are valid. If, in
this command, values of Lp = Hp = 0 or Lp + Hp * 256 > 22 inches
are used, this command is ignored and the previously set page
length is retained.
This command is immediately valid in the current print line and the
current print position becomes the top of page position. Where sin-
gle cut sheets are being fed, the current print position does not be-
come the top of page position if the menu item Page Length Con-
trol
is set to the value by Menu Setting.
This command resets the perforation skip and the top and bottom
non-printable margins. A previously selected top non-printable
area is, however, taken into account from the next page on unless
the top and bottom non-printable areas are re-defined immediately
after this command.
Set page length in
basic step sizes