10.4.3 Sensor Application 1/2
This option allows you to choose which sensor is used to control the heating
system.
• Floor:
With this setting, the floor sensor controls the heating system.
• Room/Floor Protection: With this setting, the room sensor built into the
thermostat controls the heating system while the floor sensor limits
heating according to the temperature limits set under Menu/Installer
Settings/Floor Protection.
• Room:
With this setting, the room sensor built into the thermostat controls
the heating system.
Note! Floor Protection is not active while using the Sensor Application
“Room”.
Note that certain menu options will be grayed out and inaccessible as
they are only applicable with the floor sensor.
• Regulator: With this setting, the thermostat operates as a regulator and no
sensors are used. The setting is a percentage of the full load in steps
of 10%.
Note that Floor Protection is not active when using the thermostat as
a regulator.
Note: Regulator Mode is not available with SW 1012M101.