Battery replacement

The battery is empty and needs replacing when the "     " 
battery symbol appears on the right of the LCD. Remove 
the battery cover and replace it with a battery (preferably

non-mercury) of the same type.
Please note:
The "+ " sign up and "-" sign down.
We advise you to remove the batteries if the device is not 
going to be used for a longer period of time.

Product disposal

Please ensure environmental protection. Batteries do not 
belong in the domestic waste. Please hand them in at 
collection point or the municipal recycle
material centre as special waste.The lithium
battery or fuel cell may lead to excessive
temperatures, fire or explosion.
This symbol on products and/or accompanying 
documents means that consumed electronic products 
must not be mixed with conventional domestic waste. 
Take these products to the corresponding collection 
points for correct treatment and recycling, where they
will be accepted free of charge. For more information on 
the closest collection point, Please enquire with your
local authorities.

Technical data

Type:

 maximum thermometer

Measurement range:

 (32.0~42.9)°C/(89.6-109.2)°F

Measurement  accuracy:

+/- 0.1°C/0.2°F (35.5°C~42.0°C/95.9°F~107.6°F)
+/- 0.2°C/0.4°F (32.0°C~35.5°C, 42.0°C~42.9°C/

   89.6°F~95.9°F, 107.6°F~109.2°F)

Storage/transportation temperature:

 (-25~55)°C,

≤95%RH

Ambient temperature during use:

 (5~35)°C, ≤80%RH

Atmospheric pressure: 700~1060hPa

Mode of operation of the clinical thermometer:

 direct 

mode

Transient response time:

 10s

Min Scale:

 0.1°C/0.1°F

Battery type:

Alkaline manganese battery, type LR41, 1.5V
Service life minimum 100 hours under continuous 
operation.

Weight:

 Approx. 13g

Shelf life:

 3 years

Explanation of  symbols

Kinetik DT-K11B NZ IB 20210726

Hangzhou Hua'an Medical & HealthInstruments Co., Ltd

Building 2, 1# Fuzhu Nan RD, Wuchang Town,

Yuhang District, Hangzhou, Zhejiang 310023 China

Shanghai International Holding Corp. GmbH (Europe)

Eiffestrasse 80, 20537 Hamburg Germany

E-Mail: [email protected]

Tel.: 049-40-2513175     Fax.: 049-40-255726

Legal requirements and guidelines

This product complies with the European Directive for
Medical Device 93/42/EEC and carries the CE mark, the 
device also complies with the specifications of below 
standard for:
EN 12470-3
EN 60601-1
EN 60601-1-11
EN 60601-1-2
The CE Marking confirms that this is a medical device 
with a measuring function in the sense of the medical 
device act which has undergone a conformity 
assessment procedure. A Notified body confirms that this 
product fulfills all the appropriate statutory regulations

Calibration check

This thermometer is initially calibrated at the time of 
manufacture. If this thermometer is used according to the 
operation instruction, periodic re-adjustment is not 
required.
The calibration check has to be carried out immediately,
if there are indications that the product does not keep the 
defined error limits or the calibration properties could 
have been affected by an intervention or by any other
means. Please also observe any national statutory 
regulations. The calibration check can be carried out by 
the competent authorities or by authorised service 
providers. A test instruction for calibration check can be 
provided to the relevant authorities and authorised
services providers on request.

Under the arm(axillary)
Placing the thermometer in the armpit provides a 
measurement of surface temperature that can fluctuate 
by around 0.5°C to 1.5°C from rectal temperature 
readings in adults. The usual measuring time for this 
method is approximately 23 to 29 seconds. It should be 
noted, however, that an exact reading cannot be obtained 
if, for example, the armpits have been allowed to cool. If 
this is the case, we recommend extending the measuring 
time by around 5 minutes in order to obtain the most 
precise possible reading that corresponds as closely as 
possible to the core body temperature.

In the mouth(oral)
There are different heat zones in the mouth. As a general 
rule, the oral temperature is 0.3°C to 0.8°C lower than the 
rectal temperature. To ensure that reading is as accurate 
as possible, place the thermometer tip to the left or right 
of the root of the tongue. The thermometer tip must have 
constant contact with the tissue during the reading and 
be placed under the tongue in one of the two heat 
pockets at the back, keep the mouth closed during the 
reading and breathe evenly through the nose. Do not eat 
or drink anything before the measurement. The usual 
measuring time is approximately 15 to 19 seconds.

Note: We strongly recommend the rectal method as the 
most accurate method for identifying the basal tempera- 
ture and advise you to extend the measuring time by 3 
minutes after the beep.

*Note: Normally the buzzes are "Bi-Bi-Bi-Bi-"; Alarm 
beeps more rapidly when temperature reaches 37.8°C or 
higher, and the buzzes are 
"Bi-Bi-Bi-----Bi-Bi-Bi-----Bi-Bi-Bi"

How to change the measuring scale
(only for switchable type)

To switch the display between °C and °F, turn the unit on.
Press and hold the ON/OFF button for 2 seconds, the
display will show another scale.

Cleaning and disinfection

The best way to clean the thermometer tip is by applying
a disinfectant (e.g. 70% medical alcohol) with a damp
cloth. It shall be disinfected before each use. The
Waterproof thermometers can be immersed in liquid or
lukewarm water for through cleaning and disinfection.

Safety precautions

• 

Do not allow the device to come into contact with hot 

water.

• 

Do not expose to high temperatures or direct sunlight.

• 

Do not drop the thermometer. It is neither shock-proof 

nor impact-resistant.

• 

Do not modify this device without authorization of

manufacturer.

• 

Do not clean with thinners, petrol or benzenel. Only 

clean with water or specified disinfectant.

• 

Do not use in flammable agents/oxygen rich 

environment.

• The thermometer contains small parts (battery, battery 
compartment) which can be swallowed by children. For 
this reason, do not leave the thermometer unattended in 
the hands of children.
• Avoid bending the Non-Flexible thermometer tip. which
contact patient with stainless steel cover.
• If the ambient temperature is over 35

°

C, dip the 

thermometer tip in cold water for approx. 5 to 10 seconds 
prior to measuring the temperature.
• Persistent fever, in particular in children, has to be 
treated by a doctor- please get in touch with your doctor!
• Do not use near strong electromagnetic fields, i.e. keep 
it away from any radio systems and mobile phones.

Rapid Digital Thermometer

Model: DT-K11B

0197

Congratulations on your purchase of this product. Please
read the instructions carefully before using the thermom-
eter for the first time, and keep this in a safe place.
This product is intended for the measurement of human
body temperature. This product is for home and hospital
use, operator shall be at least 11 years old and patient 
can be operator.

Operating Instructions

Before using, please disinfect the probe at first. To switch
on, press the ON/OFF button next to the display;
indicating that the thermometer is operational. At the
same time the thermometer runs a self-check test, during
which all the digital segments appear on the LCD. When
the letters "Lo" and a flashing "°C" or "°F" display, the
thermometer is ready. If the ambient temperature is below
32°C or 89.6°F, then "Lo°C" or "Lo°F" will appear on the
LCD and if it is above 42.9°C /109.2°F, then "HI°C" or 
"HI°F" will appear on the LCD.
During the reading, the current temperature is displayed
and the "°C" or "°F" symbol flashes. The measurement is
completed when a constant temperature value has been
reached. The temperature value is considered constant
when the temperature rises less than 0.1°C within 4
seconds. As soon as the constant temperature value is
reached, and the "°C" or "°F" symbol will stop flashing.
The highest temperature measured appears on the LCD.
However, please note that this thermometer is a 
maximum thermometer, i.e. the displayed temperature 
can increase slightly if measurement continues after the 
beep. This is particularly the case with axillary 
measurements, should a temperature value be recorded 
which approximates the core body temperature. In this 
instance please note the description under "Methods of 
measuring temperature". When the measurement is 
completed, please switch the thermometer off by 
pressing the ON/OFF button. After the temperature has 
been displayed, the thermometer will automatically turn 
off after 10 minutes.

Memory function

Switch the thermometer off, then press the ON/OFF 
button for about 2 seconds. The last measured value with 
"°C" or "°F" will appear automatically on the LCD. This 
display is visible as long as the ON/OFF button is held 
down. The reading is only over-written when a new 
temperature value is recorded.

Methods of measuring temperature

It is important to remember that the body temperature 
reading depends on the site where it is measured. For
this reason, the measurement site must always be 
specified in order to ensure that a correct temperature 
reading is recorded.

In the rectum(rectal)
This is the most accurate method from a medical point of
view, because it comes closest to the core body 
temperature. The thermometer tip is inserted carefully 
into the rectum for a maximum of 2 cm.
The usual measuring time is approximately 9 to 11 
seconds.

Thermometric sensor

Battery compartment

Thermometer tip

LCD

ON/OFF Button

Battery is empty

Manufactured by

Classification according to the degree of
protection against ingress of water as detailed
in IEC 60529

Read the instructions (actual symbol colours
are white on a blue background)

Product disposal instructions for electronic
devices

The battery in this product complies with the
requirements stated in European  Directives
2006/66/EEC

Type BF equipment

Manufacture date

CE conformity marking

Stand by

Lo°C or Lo°F: temperature under 32°C or 89.6°F
HI°C or HI°F: temperature over 42.9°C or 109.2°F

Support

Our manual should provide you with all the information 
you need to set up and use this product. 

If you have a question, have a look at our Troubleshooting 
page! 

For further assistance, why not contact our Customer 
Care team directly? We’re here to help!

Our Customer Care team are available from 9am-5pm, 
Monday to Friday (excluding bank holidays).

We promise to respond to all queries and will ensure to 
resolve any issue you may be having.

You can reach us by…

Live Chat:

Simply visit www.kinetikwellbeing.com and send us a 
message.

Email:

[email protected]

Phone (UK):

+44 1483 937967

Post (UK):

Kinetik Medical Devices Limited

Unit 3, Perrywood Business Park, Honeycrock Lane, 
Salfords, Redhill. RH1 5DZ

Phone (NZ):

(09) 801 0627

Post (NZ):

Kinetik Wellbeing NZ 

44 John Brian Drive, 0794 Redvale, Albany,
Auckland, NewZealand

用AI或EPS

案印刷。 

PDF文

只供参考,不可用于印刷, 

留意。

By cmlam at 3:52 pm, Jul 26, 2021

Reviews: