Monitoring of energy consumption
The thermostat calculates average time it has been switched on allowing you to monitor your energy consumption.
In the thermostat you can read out:. Total switch-on time in percentage in the latest 2 days, 30 days or 365 days.
Calculation of operational costs per day:
(switch-on time:100) x kW x kWh-price x 24 h per day
Example:
Read-out: 30 % in the latest 365 days
Size of heating system: 1,2 kW (ask the installer)
Cost of power: 0,2 EUR / kWh
Calculation: (30:100) x 1,2 kW x 0,2 EUR / kWh x 24 h = 1,7 EUR per day
4. Advanced settings and read-out
4-event sequence
The present event sequence flashes: Days 1-5, followed by days 6-7. To change, press the UP (
) button until you have days 1-6
and then day 7 flashing, or all 7 days are flashing. Select the required sequence with the OK (
) button.
☞
✚
☞
☞
5-2: 4 events in 5 days +
2 events in 2 days.
6-1: 4 events in 6 days +
2 events in 1 day
7-0: 4 events in 7 days
☞
☞
}
2 days
30 days
365 days
Software version
Actual sensor temperature
}
Max and min allowed temperature range
The temperature setting range of +5˚ to 40˚ C can be limited to prevent at comfort or manual mode a too high or too low temperature
being selected. For example, a wood floor covering should not be allowed to exceed a maximum of 27˚C. Low limitation is used where
the temperature of the floor is required never to fall below the minimum set temperature.
Time and temperature scale selection
Adaptive function
This function enables the thermostat to calculate when it needs to switch ON so that the required temperature is reached at the set
time. With a start time of 07:00 therefore, the thermostat may switch ON as early as 06:00 so that the desired temperature of 25˚C is
achieved by 07:00. Without this function set, the thermostat will start to heat at the time you set.
☞
☞
☞
☞
Maximum allowed temperature setting. Use the UP (
) or
DOWN (
) button to increase or reduce, and OK (
) button to
accept.
Next is displayed LoLi. Press OK (
) button to continue.
Minimum allowed temperature setting. Use the UP (
) or
DOWN (
) button to increase or reduce and OK (
) button to
accept.
You can select either ˚C or ˚F scale, and 12 or 24 hour clock as
follows:
Press UP (
) or DOWN (
) button to change settings. Confirm
the required scale with the OK button (
) button.
☞
☞
}
}
☞
☞
☞
☞
☞
Press the DOWN (
) button to switch between on and off.
Press OK (
) button to confirm.
Press OK (
) button to end programming and to return to
scheduled programme.
☞
☞
☞
☞
Press both UP (
) and DOWN (
) buttons together for 3 seconds. INFO is displayed.
Press UP(
) button until you reach the desired sub menu. Select the sub menu with the OK (
) button.
Press UP (
) or DOWN (
) button to show the different
readouts.
No changes can be made here. Use the OK (
) button to end.
© 2009 OJ Electronics A/S · ® The OJ trademark is a registred trademark belonging to OJ Electronics A/S