Constant
pressure mode
LED1
Green
LED2
Green
LED3
Yellow
LED4
Yellow
LED5
Yellow
Constant pressure
mode 1
X
X
Constant pressure
mode 2
X
X
X
Constant pressure
mode 3
X
X
X
X
Auto
Adapt
X
Constant
curve mode
LED1
Green
LED2
Green
LED3
Yellow
LED4
Yellow
LED5
Yellow
Constant curve
mode 1
X
Constant curve
mode 2
X
X
Constant curve
mode 3
X
X
X
Changing the operating mode
1. Press and hold the button for more than 2 seconds.
2. Scroll between operating modes by pressing the button.
3. Once you have reached the right operating mode, wait for 10 seconds, and the
setting will be saved.
2.6.9 HVAC checklist
Check the following:
1. All joints are tight.
2. The expansion tanks for the heating system and the filling unit expansion tank have
been installed appropriately.
3. The safety valve discharge pipe and the pressure gauge for the heating system
have been installed appropriately.
4. The heating system has been appropriately filled and bled of air.
5. The brine circuit has been appropriately installed, filled, and bled of air.
2.7 Electrical installation and external sensors
Electrical installation is to be carried out by authorized and trained
personnel only.
When making electrical connections, refer to the connection diagrams supplied with the
unit.
Accessing the unit’s control cabinet
The heat pump’s control cabinet is located inside the heat pump, under the crown plate
of the heat pump (see section
Detaching the crown plate
). The control cabinet’s cover
can be removed without removing the crown plate.
M8011 2204EN
21 (70)
Summary of Contents for VSi 6-14
Page 1: ...M8011 2204EN 25 January 2022 Installation and operation manual VSi 6 14 VMi 6 17 ss Control...
Page 2: ......
Page 59: ...Dimensional drawings VSi 10VS14_2 VSI 1 ver 1 10VS14_2 VSI 2 ver 1 M8011 2204EN 57 70...
Page 60: ...Dimensional drawings VMi 10VMI141_2 VMI 1 ver 1 10VMI141_2 VMI 2 ver 1 58 70 M8011 2204EN...
Page 73: ......