Type labelling
Label element 1: Series, fuel
KP
Light fuel oil
RP
Heavy fuel oil
GP
Gas
GKP
Light fuel oil
GRP
Gas, heavy fuel oil
Label element 2: Burner frame size categorization
50... 1200 Higher value = higher capacity
Label element 3: Method of control
H
Two-stage
M
Modulating
MH
Modulating gas, two-stage oil
ME
Modulating with a separate fan
Label element 4: Burner capacity size categorization
-, I, II, III
Higher value = higher capacity
Label element 5: Control system (additional code):
WD100
Electronic fuel/air ratio control system
WD200
Electronic fuel/air ratio control system with O2 control and variable speed drive (VSD)
Label element 6: Combustion head type referring to typical NOx-emissions (additional code)
LN30
LN60
LN80
LN30 = 30mg/kWh
LN60 = 60mg/kWh
LN80 = 80mg/kWh
Label element 7: Combustion head length (additional code)
-, C1, C2, C3 Combustion head length C only in use in LN80 burners.
Type plate
The following illustration shows an example of the type plate of Oilon burners:
8 (111)
M4219 2305EN
Summary of Contents for GP-600 M
Page 2: ......
Page 16: ...Block diagram of contact links Block diagram ver 7 14 111 M4219 2305EN...
Page 87: ...5 5 Time sequence diagram gas use 7550f57e 0515 Gp1 ver 6 M4219 2305EN 85 111...
Page 113: ...M4219 2305EN 111 111...
Page 114: ...112 111 M4219 2305EN...
Page 115: ......