6.1.4.4
Circuit Diagram
•
OP 16 PLUGGED
•
OP 9 PLUGGED
•
OP 6 PLUGGED
•
The customer-supplied Remote
Compensator/Load Sense circuit is
plumbed into the LS/RP Port, with the Load
Sense Signal. The circuit requires a Ø 0.031
in. orifice between the Remote
Compensator and Load Sense components.
•
The Remote Compensator requires a
flowrate of approximately 0.25 GPM.
All internal plugs and orifices use 1/16 NPT
plugs and 5/32 internal hex wrenches.
6.1.5
Reconfiguring the Pressure Comp./Load Sense Control
A PC/LS Control on an existing XD5 pump can be reconfigured between its 4 options by adding or removing plugs and
orifices from ports in the Valve Plate. The location of the ports is shown in
. The combination of orifices and
plugs required for each configuration is given in the preceding subsections of
Section 6.1
Figure 12 - Control Port Locations